Fully validated LC-MS/MS assay for the simultaneous quantitation of coadministered therapeutic antibodies in cynomolgus monkey serum.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jiang Hao, Zeng Jianing, Titsch Craig, Voronin Kimberly, Akinsanya Billy, Luo Linlin, Shen Hongwu, Desai Dharmesh D, Allentoff Alban, Aubry Anne-Françoise, Desilva Binodh S, Arnold Mark E

Аннотация

An LC-MS/MS assay was developed and fully validated for the simultaneous quantitation of two coadministered human monoclonal antibodies (mAbs), mAb-A and mAb-B of IgG4 subclass, in monkey serum. The total serum proteins were digested with trypsin at 50 °C for 30 min after methanol denaturation and precipitation, dithiothreitol reduction, and iodoacetamide alkylation. The tryptic peptides were chromatographically separated with a C18 column (2.1 × 100 mm, 1.7 μm) with mobile phases of 0.1% formic acid in water and acetonitrile. Four peptides, a unique peptide for each mAb and two confirmatory peptides from different antibody domains, were simultaneously quantified by LC-MS/MS in the multiple reaction-monitoring mode. Stable isotopically labeled peptides with flanking amino acids on C- and N-terminals were used as internal standards to minimize the variability during sample processing and detection. The LC-MS/MS assay showed lower limit of quantitation (LLOQ) at 5 μg/mL for mAb-A and 25 μg/mL for mAb-B. The intra- and interassay precision (%CV) was within 10.0% and 8.1%, respectively, and the accuracy (%Dev) was within ±5.4% for all the peptides. Other validation parameters, including sensitivity, selectivity, dilution linearity, processing recovery and matrix effect, autosampler carryover, run size, stability, and data reproducibility, were all evaluated. The confirmatory peptides played a critical role in confirming quantitation accuracy and the integrity of the drugs in the study samples. The robustness of the LC-MS/MS assay and the data agreement with the ligand binding data demonstrated that LC-MS/MS is a reliable and complementary approach for the quantitation of coadministered antibody drugs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты