OBJECTIVE

Discrepancies or inaccuracies between testing methods can create confusion or lead to clinical harm if antibiotics are inappropriately chosen. We report our clinical experience using the Accelerate Pheno™ followed by routine automated susceptibilities by the Vitek®2 for positive blood cultures with gram-negative rods.

DESIGN

This was a retrospective review of positive gram-negative blood cultures, including comparison of susceptibility testing results and impact on clinical care.

SETTING

Academic teaching hospital.

PATIENTS

PARTICIPANTS

All patients admitted to the hospital with gram-negative bacteremia from January 2020 to December 2022.

METHODS

Microbiology was reviewed for discrepancies as defined by very major errors (VMEs), major errors (MEs), and minor errors (mEs). Clinical charts were reviewed for antibiotic therapy.

RESULTS

Positive blood cultures with gram-negative rods were included (n = 262). Between these two methods, overall essential agreement was 93.7% (2162/2304) and categorical agreement 93.5% (2159/2306). There were 147 discrepancies noted, including 6 VMEs, 25 MEs, and 116 mEs accounting for 96 patients. Antibiotic choice was changed in 8 patients due to perceived suboptimal empiric therapy based on the rapid susceptibility results.

CONCLUSIONS

The Accelerate Pheno tended to over-call resistance compared to the Vitek®2. Few patients (8) received the incorrect antibiotic based on the Pheno result. Stewardship programs may choose to optimize their rapid antibiotic susceptibility testing reporting to help minimize confusion and guide appropriate antibiotic selection.

Для цитирования: Freeman Weiss Zoe, Zelenkov Dimitar, Englert Jon, Campion Maureen. Delving into discrepancies, a single-center experience with Accelerate Pheno for gram-negative bacteremia, a rapid phenotypic susceptibility testing method.. Antimicrobial stewardship & healthcare epidemiology : ASHE. 2025. DOI: 10.1017/ash.2024.482.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.