Медицинская библиотека · Academic radiology · 2025

Enhanced Image Quality and Comparable Diagnostic Performance of Prostate Fast Bi-MRI with Deep Learning Reconstruction.

Shen Liting, Yuan Ying, Liu Jin, Cheng Yue, Liao Qian, Shi Rongchao, Xiong Tianyu, Xu Hui, Wang Liang, Yang Zhenghan

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

RATIONAL AND

OBJECTIVES

To evaluate image quality and diagnostic performance of prostate biparametric MRI (bi-MRI) with deep learning reconstruction (DLR).

MATERIALS AND

METHODS

This prospective study included 61 adult male urological patients undergoing prostate MRI with standard-of-care (SOC) and fast protocols. Sequences included T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and apparent diffusion coefficient (ADC) maps. DLR images were generated from FAST datasets. Three groups (SOC, FAST, DLR) were compared using: (1) five-point Likert scale, (2) signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), (3) lesion slope profiles, (4) dorsal capsule edge rise distance (ERD). PI-RADS scores were assigned to dominant lesions. ADC values were measured in histopathologically confirmed cases. Diagnostic performance was analyzed via receiver operating characteristic (ROC) curves (accuracy/sensitivity/specificity). Statistical tests included Friedman test, one-way ANOVA with post hoc analyses, and DeLong test for ROC comparisons (P<0.05).

RESULTS

FAST scanning protocols reduced acquisition time by nearly half compared to the SOC scanning protocol. When compared to T2WIFAST, DLR significantly improved SNR, CNR, slope profile, and ERD (P < 0.05). Similarly, DLR significantly enhanced SNR, CNR, and image sharpness when compared to DWIFAST (P < 0.05). No significant differences were observed in PI-RADS scores and ADC values between groups (P > 0.05). The areas under the ROC curves, sensitivity, and specificity of ADC values for distinguishing benign and malignant lesions remained consistent (P > 0.05).

CONCLUSION

DLR enhances image quality in fast prostate bi-MRI while preserving PI-RADS classification accuracy and ADC diagnostic performance.

Для цитирования: Shen Liting, Yuan Ying, Liu Jin, Cheng Yue, Liao Qian, Shi Rongchao, Xiong Tianyu, Xu Hui, Wang Liang, Yang Zhenghan. Enhanced Image Quality and Comparable Diagnostic Performance of Prostate Fast Bi-MRI with Deep Learning Reconstruction.. Academic radiology. 2025. DOI: 10.1016/j.acra.2025.06.059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.