Enhanced Image Quality and Comparable Diagnostic Performance of Prostate Fast Bi-MRI with Deep Learning Reconstruction.
Аннотация
RATIONAL AND
OBJECTIVES
To evaluate image quality and diagnostic performance of prostate biparametric MRI (bi-MRI) with deep learning reconstruction (DLR).
MATERIALS AND
METHODS
This prospective study included 61 adult male urological patients undergoing prostate MRI with standard-of-care (SOC) and fast protocols. Sequences included T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and apparent diffusion coefficient (ADC) maps. DLR images were generated from FAST datasets. Three groups (SOC, FAST, DLR) were compared using: (1) five-point Likert scale, (2) signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), (3) lesion slope profiles, (4) dorsal capsule edge rise distance (ERD). PI-RADS scores were assigned to dominant lesions. ADC values were measured in histopathologically confirmed cases. Diagnostic performance was analyzed via receiver operating characteristic (ROC) curves (accuracy/sensitivity/specificity). Statistical tests included Friedman test, one-way ANOVA with post hoc analyses, and DeLong test for ROC comparisons (P<0.05).
RESULTS
FAST scanning protocols reduced acquisition time by nearly half compared to the SOC scanning protocol. When compared to T2WIFAST, DLR significantly improved SNR, CNR, slope profile, and ERD (P < 0.05). Similarly, DLR significantly enhanced SNR, CNR, and image sharpness when compared to DWIFAST (P < 0.05). No significant differences were observed in PI-RADS scores and ADC values between groups (P > 0.05). The areas under the ROC curves, sensitivity, and specificity of ADC values for distinguishing benign and malignant lesions remained consistent (P > 0.05).
CONCLUSION
DLR enhances image quality in fast prostate bi-MRI while preserving PI-RADS classification accuracy and ADC diagnostic performance.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.