MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.120.009261

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2021

Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study.

Su Lan, Wang Songjie, Wu Shengjie, Xu Lei, Huang Zhouqing, Chen Xiao, Zheng Rujie, Jiang Limeng, Ellenbogen Kenneth A, Whinnett Zachary I, Huang Weijian

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Left bundle branch pacing (LBBP) is a novel pacing method and has been observed to have low and stable pacing thresholds in prior small short-term studies. The objective of this study was to evaluate the feasibility and safety of LBBP in a large consecutive diverse group of patients with long-term follow-up.

METHODS

This study prospectively enrolled 632 consecutive pacemaker patients with attempted LBBP from April 2017 to July 2019. Pacing parameters, complications, ECG, and echocardiographic measurements were assessed at implant and during follow-up of 1, 6, 12, and 24 months.

RESULTS

LBBP was successful in 618/632 (97.8%) patients according to strict criteria for LBB capture. Mean follow-up time was 18.6±6.7 months. Two hundred thirty-one patients had follow-up over 2 years. LBB capture threshold at implant was 0.65±0.27 mV at 0.5 ms and 0.69±0.24 mV at 0.5 ms at 2-year follow-up. A significant decrease in QRS duration was observed in patients with left bundle branch block (167.22±18.99 versus 124.02±24.15 ms, P<0.001). Postimplantation left ventricular ejection fraction improved in patients with QRS≥120 ms (48.82±17.78% versus 58.12±13.04%, P<0.001). The number of patients with moderate and severe tricuspid regurgitation decreased at 1 year. Permanent right bundle branch injury occurred in 55 (8.9%) patients. LBB capture threshold increased to >3 V or loss of bundle capture in 6 patients (1%), 2 patients of them had a loss of conduction system capture. Two patients required lead revision due to dislodgement.

CONCLUSIONS

This large observational study suggests that LBBP is feasible with high success rates and low complication rates during long-term follow-up. Therefore, LBBP appears to be a reliable method for physiological pacing for patients with either a bradycardia or heart failure pacing indication.

Для цитирования: Su Lan, Wang Songjie, Wu Shengjie, Xu Lei, Huang Zhouqing, Chen Xiao, Zheng Rujie, Jiang Limeng, Ellenbogen Kenneth A, Whinnett Zachary I, Huang Weijian. Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study.. Circulation. Arrhythmia and electrophysiology. 2021. DOI: 10.1161/circep.120.009261.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.