MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.crad.2021.02.019

Медицинская библиотека · Clinical radiology · 2021

Simultaneous assessment of coronary flow reserve and left ventricular function during vasodilator stress evaluated by 13N-ammonia hybrid PET/MRI.

Kiko T, Yokokawa T, Masuda A, Misaka T, Yamada S, Kaneshiro T, Oikawa M, Yoshihisa A, Nakazato K, Takeishi Y

СтатьяПеревод в очереди

Аннотация

AIM: To explore changes in left ventricular (LV) function and the relationship of these changes with myocardial blood flow (MBF) evaluated by 13N-ammonia hybrid positron-emission tomography (PET)/magnetic resonance imaging (MRI) during vasodilator stress in patients with suspected coronary artery disease (CAD).

MATERIALS AND

METHODS

Fifty-two consecutive patients with suspected CAD, who underwent 13N-ammonia PET/MRI, were enrolled. Vasodilator stress was induced by intravenous injection of adenosine. MBF and coronary flow reserve (CFR) were calculated from dynamic acquisition of 13N-ammonia PET. LV function was evaluated by MRI both at rest and during vasodilator stress. An abnormal perfusion on myocardial images was defined as a summed difference score of ≥4.

RESULTS

MRI showed that the LV end-diastolic volume, LV end-systolic volume, and LV ejection fraction (LVEF) remained unchanged during vasodilator stress in all patients (n=52) as well as in the patients with CFR of <2 (n=27), stress MBF of <1.3 ml/g/min (n=28), abnormal myocardial perfusion (n=30), and more than one diseased vessel (n=46). In only four patients, the LVEF measured by MRI decreased by >5% during vasodilator stress. In these four patients, CFR was lower (1.57 ± 0.12 versus 2.18 ± 0.86, p<0.01) and the number of diseased vessels was higher (2.75 ± 0.50 versus 1.48 ± 0.92, p<0.01) than in patients without post-stress LV dysfunction.

CONCLUSION

The LV volume and systolic function evaluated by cardiac MRI remained unchanged during vasodilator stress; however, LV dysfunction during vasodilator stress may occur in patients with severe CAD.

Для цитирования: Kiko T, Yokokawa T, Masuda A, Misaka T, Yamada S, Kaneshiro T, Oikawa M, Yoshihisa A, Nakazato K, Takeishi Y. Simultaneous assessment of coronary flow reserve and left ventricular function during vasodilator stress evaluated by 13N-ammonia hybrid PET/MRI.. Clinical radiology. 2021. DOI: 10.1016/j.crad.2021.02.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.