MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7326/0003-4819-150-12-200906160-00119

Медицинская библиотека · Annals of internal medicine · 2009

Stent placement in patients with atherosclerotic renal artery stenosis and impaired renal function: a randomized trial.

Bax Liesbeth, Woittiez Arend-Jan J, Kouwenberg Hans J, Mali Willem P T M, Buskens Erik, Beek Frederik J A, Braam Branko, Huysmans Frans T M, Schultze Kool Leo J, Rutten Matthieu J C M, Doorenbos Cornelius J, Aarts Johannes C N M, Rabelink Ton J, Plouin Pierre-François, Raynaud Alain, van Montfrans Gert A, Reekers Jim A, van den Meiracker Anton H, Pattynama Peter M T, van de Ven Peter J G, Vroegindeweij Dammis, Kroon Abraham A, de Haan Michiel W, Postma Cornelis T, Beutler Jaap J

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Little is known about the efficacy and safety of renal artery stenting in patients with atherosclerotic renal artery stenosis (ARAS) and impaired renal function.

OBJECTIVE

To determine the efficacy and safety of stent placement in patients with ARAS and impaired renal function.

DESIGN

Randomized clinical trial. Randomization was centralized and computer generated, and allocation was assigned by e-mail. Patients, providers, and persons who assessed outcomes were not blinded to treatment assignment.

SETTING

10 European medical centers.

PARTICIPANTS

140 patients with creatinine clearance less than 80 mL/min per 1.73 m(2) and ARAS of 50% or greater.

INTERVENTION: Stent placement and medical treatment (64 patients) or medical treatment only (76 patients). Medical treatment consisted of antihypertensive treatment, a statin, and aspirin.

MEASUREMENTS: The primary end point was a 20% or greater decrease in creatinine clearance. Secondary end points included safety and cardiovascular morbidity and mortality.

RESULTS

Forty-six of 64 patients assigned to stent placement had the procedure. Ten of the 64 patients (16%) in the stent placement group and 16 patients (22%) in the medication group reached the primary end point (hazard ratio, 0.73 [95% CI, 0.33 to 1.61]). Serious complications occurred in the stent group, including 2 procedure-related deaths (3%), 1 late death secondary to an infected hematoma, and 1 patient who required dialysis secondary to cholesterol embolism. The groups did not differ for other secondary end points.

LIMITATION: Many patients were falsely identified as having renal artery stenosis greater than 50% by noninvasive imaging and did not ultimately require stenting.

CONCLUSION

Stent placement with medical treatment had no clear effect on progression of impaired renal function but led to a small number of significant procedure-related complications. The study findings favor a conservative approach to patients with ARAS, focused on cardiovascular risk factor management and avoiding stenting.

Для цитирования: Bax Liesbeth, Woittiez Arend-Jan J, Kouwenberg Hans J, Mali Willem P T M, Buskens Erik, Beek Frederik J A, Braam Branko, Huysmans Frans T M, Schultze Kool Leo J, Rutten Matthieu J C M, Doorenbos Cornelius J, Aarts Johannes C N M, Rabelink Ton J, Plouin Pierre-François, Raynaud Alain, van Montfrans Gert A, Reekers Jim A, van den Meiracker Anton H, Pattynama Peter M T, van de Ven Peter J G, Vroegindeweij Dammis, Kroon Abraham A, de Haan Michiel W, Postma Cornelis T, Beutler Jaap J. Stent placement in patients with atherosclerotic renal artery stenosis and impaired renal function: a randomized trial.. Annals of internal medicine. 2009. DOI: 10.7326/0003-4819-150-12-200906160-00119.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.