MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2013.05.019

Медицинская библиотека · Analytica chimica acta · 2013

Evaluation and optimization of solid adsorbents for the sampling of gaseous methylated mercury species.

Baya Pascale A, Hollinsworth Jenny Leigh, Hintelmann Holger

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This study evaluates the suitability of commercially available adsorbents for the measurement of gaseous organic mercury species namely monomethylmercury (MMHg) and dimethylmercury (DMHg). Bond Elut ENV (BE), a new generation of divinylbenzene (DVB), is evaluated the first time for simultaneous sampling and quantification of ultra-trace levels of MMHg and DMHg in air and its performance compared against Carbotrap(®) B (CB) and Tenax(®) TA (TA), two commonly used adsorbents for mercury solid phase adsorption. The suitability of TA as an absorbent for MMHg (recovery 100±8.1%) but less so for DMHg (recovery 64±17.3%) was confirmed while the reverse was observed for CB with an average recovery of 100±0.3% for DMHg but only 61±32.5% for MMHg. BE is the only adsorbent that showed excellent performance for trapping both Hg species with recoveries of 98±9.2% and 95±8.1% for MMHg and DMHg, respectively. Furthermore, BE exhibited much higher sampling capacities (>100L at 4°C) and preservation of sample integrity (>1 month at -20°C in the dark). Overall, BE proves to be the most suitable adsorbent for simultaneous trapping of organic Hg species with high sampling capacity and sample stability but also very good chromatographic properties which are desirable characteristics for both collection traps and analytical traps. Bond Elut ENV is proposed as an alternative to both Tenax(®) TA and Carbotrap(®) B with additional advantages of offering more versatility and sampling options.

Для цитирования: Baya Pascale A, Hollinsworth Jenny Leigh, Hintelmann Holger. Evaluation and optimization of solid adsorbents for the sampling of gaseous methylated mercury species.. Analytica chimica acta. 2013. DOI: 10.1016/j.aca.2013.05.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.