MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/147323001204000119

Медицинская библиотека · The Journal of international medical research · 2012

The diagnostic value of a multivariate logistic regression analysis model with transvaginal power Doppler ultrasonography for the prediction of ectopic pregnancy.

Chen Z-Y, Liu J-H, Liang K, Liang W-X, Ma S-H, Zeng G-J, Xiao S-Y, He J-G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

A multivariate logistic regression analysis model for predicting ectopic pregnancy in women with pregnancy of unknown location was designed and evaluated clinically.

METHODS

Endometrial thickness, symmetry, resonance, pattern of echogenicity, helicine artery blood flow and blood flow resistance index (RI) in 129 patients with suspected early ectopic pregnancy were assessed by transvaginal power Doppler ultrasonography. Variables significant in univariate logistic regression analysis were included in a multivariate predictive logistic regression analysis model.

RESULTS

The final predictive model included three factors: endometrial thickness≤9 mm; a multilayered endometrial echogenicity pattern with prominent outer and midline hyperechogenic lines and an inner hypoechogenic region; and visible endometrial arterial blood flow. The area under the receiver operating characteristic curve of the model was 0.980. When RI was >0.65 and the predictive probability>0.50, diagnostic accuracy was high. The model correctly diagnosed 52/55 (94.5%) clinically confirmed ectopic pregnancy cases.

CONCLUSION

This multivariate predictive logistic regression analysis model has clinical value for the differential diagnosis of early ectopic pregnancy when the pregnancy location is unknown.

Для цитирования: Chen Z-Y, Liu J-H, Liang K, Liang W-X, Ma S-H, Zeng G-J, Xiao S-Y, He J-G. The diagnostic value of a multivariate logistic regression analysis model with transvaginal power Doppler ultrasonography for the prediction of ectopic pregnancy.. The Journal of international medical research. 2012. DOI: 10.1177/147323001204000119.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.