OBJECTIVE

To discuss the surgical techniques and therapeutic effects of phacofragmentation of the dislocated lens in the vitreous cavity.

METHODS

Phacofragmentation was performed on 23 eyes of 23 patients with dislocated lens or subluxated lens in the vitreous cavity. With high suction and moderate ultrasound, the nucleus could be emulsified. Energy and time of emulsification: 50%-60% of energy was set up and emulsification spent 43 s to 3 min 23 s (mean 1 min 57 s). The pressure of maximum vacuum aspiration was 110-120 mm Hg (1 mm Hg = 0.133 kPa). In 11 eyes, anterior chamber intraocular lens (ACIOL) was implanted. Cryoapplications and encircling procedure were also performed on one eye.

RESULTS

Phacofragmentation was successful in all patients. After follow-up for 5-19 months (mean 7.2 months), the corrected visual acuity was obviously improved in the cases of ACIOL and Marfan's syndrome, with 12 patients achieving visual acuity of 0.12-0.6. The major complications were corneal edema and damage of iris.

CONCLUSIONS

It is demonstrated that phacofragmentation in the central vitreous cavity is safe and fairly easy procedure without adverse effects on retina and sclera. It helps to reduce intraoperative risks of alternative methods, avoiding a large opening of the anterior chamber and hypotony of the globe.

Для цитирования: Du X, Jiang J, Yao K. [Phacofragmentation of dislocated lens in vitreous cavity].. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.