Sinus Arrest and Bradycardia Induced by Carotid Baroreceptor Reflex Activation during Rotational Angiography: A Case Report.

Kojima Atsuhiro, Saga Isako, Kanki Hideaki, Negishi Miho, Iwama Takashi

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE

We describe a rare patient with a cavernous sinus dural arteriovenous fistula (CS DAVF) in whom diagnostic rotational angiography (RA) caused sinus arrest and bradycardia.

CASE PRESENTATION: A 79-year-old woman with no previous history of cardiovascular diseases presented with left oculomotor nerve paresis. Conventional angiography confirmed a bilateral CS DAVF. During a three-dimensional RA (3DRA) examination of the left internal carotid artery, sinus arrest occurred. Subsequently, the use of 3DRA to image the left external carotid artery and the use of cone beam computed tomography (CBCT) to image the left internal and external carotid artery also caused transient sinus bradycardia. Two weeks later, we inserted a temporary transvenous pacemaker and completed the transvenous embolization of the left CS DAVF. The left oculomotor paresis improved without any perioperative complications.

CONCLUSION

RA is a standard radiological modality for the diagnosis of cerebrovascular disease. Although the physical force generated by the injection of the contrast medium at the carotid bifurcation can theoretically cause hemodynamic instability, no previous reports have described sinus arrest or bradycardia in association with diagnostic carotid angiography. The present case demonstrates that 3DRA and CBCT can provoke rare, but serious, incidences of cardiac arrhythmia.

Для цитирования: Kojima Atsuhiro, Saga Isako, Kanki Hideaki, Negishi Miho, Iwama Takashi. Sinus Arrest and Bradycardia Induced by Carotid Baroreceptor Reflex Activation during Rotational Angiography: A Case Report.. Journal of neuroendovascular therapy. 2021. DOI: 10.5797/jnet.cr.2020-0166.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.