DOI 10.1016/j.talanta.2022.123267
Fast screening of saxitoxin, neosaxitoxin, and decarbamoyl analogues in fresh and brackish surface waters by on-line enrichment coupled to HILIC-HRMS.
Аннотация
The proliferation of harmful cyanobacterial algal blooms is of concern due to the associated release of toxins affecting ecosystems and human health. The paralytic shellfish poison saxitoxin (STX) is a small polar alkaloid that can occur in inland and marine aquatic environments. Here, we optimized a fast and sensitive analytical method for the determination of STX, neosaxitoxin (NeoSTX), and their decarbamoyl analogues in surface waters. The method involves a simple filtration, addition of isotope-labelled internal standard (ILIS), and analysis by on-line solid-phase extraction coupled to hydrophilic interaction liquid chromatography high-resolution mass spectrometry (on-line SPE-HILIC-HRMS). Except glass fiber filters, other tested materials (e.g., nylon, nitrocellulose) provided suitable filtration performance. Time-dependent adsorptive losses occurred during the LC-MS batch sequence if glass autosampler vials were used, while no such effect was observed for polypropylene autosampler vials. Matrix effects were evaluated for 4 different quantification scenarios, including external vs. internal curves and neat reagent water vs. matrix-matched curves. Matrix-matched calibration with ILIS correction (NeoSTX-15N7) provided the best performance overall. The analytical method was validated in freshwater lake water and estuarine brackish water (30‰ salinity), with suitable determination coefficients (R2 > 0.9975), matrix spike accuracy (90-107%), and intraday/interday precision (RSD of 0.61-16%). Method limits of detection (LOD in lake water: 0.72-3.9 ng/L) are also improved over most of the recent literature. The method was applied to a set of 302 surface water samples collected in Canada, France, and the United Kingdom, and positive detections were reported for STX (max: 98 ng/L), decarbamoyl-STX (max: 15 ng/L), and NeoSTX (max: 87 ng/L).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.