Медицинская библиотека · Journal of translational medicine · 2023

Validation of circulating histone detection by mass spectrometry for early diagnosis, prognosis, and management of critically ill septic patients.

García-Giménez José Luis, García-López Eva, Mena-Mollá Salvador, Beltrán-García Jesús, Osca-Verdegal Rebeca, Nacher-Sendra Elena, Aguado-Velasco Carmen, Casabó-Vallés Germán, Romá-Mateo Carlos, Rodriguez-Gimillo María, Antúnez Oreto, Ferreres José, Pallardó Federico V, Carbonell Nieves

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

As leading contributors to worldwide morbidity and mortality, sepsis and septic shock are considered a major global health concern. Proactive biomarker identification in patients with sepsis suspicion at any time remains a daunting challenge for hospitals. Despite great progress in the understanding of clinical and molecular aspects of sepsis, its definition, diagnosis, and treatment remain challenging, highlighting a need for new biomarkers with potential to improve critically ill patient management. In this study we validate a quantitative mass spectrometry method to measure circulating histone levels in plasma samples for the diagnosis and prognosis of sepsis and septic shock patients.

METHODS

We used the mass spectrometry technique of multiple reaction monitoring to quantify circulating histones H2B and H3 in plasma from a monocenter cohort of critically ill patients admitted to an Intensive Care Unit (ICU) and evaluated its performance for the diagnosis and prognosis of sepsis and septic shock (SS).

RESULTS

Our results highlight the potential of our test for early diagnosis of sepsis and SS. H2B levels above 121.40 ng/mL (IQR 446.70) were indicative of SS. The value of blood circulating histones to identify a subset of SS patients in a more severe stage with associated organ failure was also tested, revealing circulating levels of histones H2B above 435.61 ng/ml (IQR 2407.10) and H3 above 300.61 ng/ml (IQR 912.77) in septic shock patients with organ failure requiring invasive organ support therapies. Importantly, we found levels of H2B and H3 above 400.44 ng/mL (IQR 1335.54) and 258.25 (IQR 470.44), respectively in those patients who debut with disseminated intravascular coagulation (DIC). Finally, a receiver operating characteristic curve (ROC curve) demonstrated the prognostic value of circulating histone H3 to predict fatal outcomes and found for histone H3 an area under the curve (AUC) of 0.720 (CI 0.546-0.895) p < 0.016 on a positive test cut-off point at 486.84 ng/mL, showing a sensitivity of 66.7% and specificity of 73.9%.

CONCLUSIONS

Circulating histones analyzed by MS can be used to diagnose SS and identify patients at high risk of suffering DIC and fatal outcome.

Для цитирования: García-Giménez José Luis, García-López Eva, Mena-Mollá Salvador, Beltrán-García Jesús, Osca-Verdegal Rebeca, Nacher-Sendra Elena, Aguado-Velasco Carmen, Casabó-Vallés Germán, Romá-Mateo Carlos, Rodriguez-Gimillo María, Antúnez Oreto, Ferreres José, Pallardó Federico V, Carbonell Nieves. Validation of circulating histone detection by mass spectrometry for early diagnosis, prognosis, and management of critically ill septic patients.. Journal of translational medicine. 2023. DOI: 10.1186/s12967-023-04197-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.