The International journal of oral & maxillofacial implants · 2012
Experimental custom-made zirconia abutments for narrow implants in esthetically demanding regions: a 5-year follow-up.
Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Vanlıoglu Burçin Akoglu, Özkan Yasar, Evren Buket, Özkan Yasemin Kulak
Аннотация
PURPOSE: This prospective clinical study evaluated an experimental custom-made zirconia abutment with respect to peri-implant hard and soft tissue reaction in narrow implants.
MATERIALS AND METHODS: Patients were treated with prefabricated titanium implants and custom-made zirconia abutments. All-ceramic crowns were fabricated and cemented with resin cement. Clinical parameters such as Plaque Index, Sulcus Bleeding Index, peri-implant probing depth, and radiographic marginal bone loss levels were recorded, along with any biologic and mechanical complications, at baseline and up to 5 years.
RESULTS: Twelve patients with missing maxillary lateral incisors treated with a total of 23 implants were evaluated. Thirteen Straumann Narrow Neck Solid Screw implants with a diameter of 3.3 mm and 10 Astra MicroThread implants with a diameter of 3.5 mm were used. Six patients with 11 implants were treated with custom-made zirconia abutments and prefabricated metal abutments were used in the control group. Implant and abutment success at 5 years was 100%. No abutment fractures occurred. Abutment screw loosening was reported for one restoration at the 1-year recall. Mean marginal bone loss measured 0.21 mm after 5 years of functional loading.
CONCLUSION: Custom-made zirconia abutments offered sufficient stability to support all-ceramic restorations over narrow implants in anterior regions over a 5-year period. The soft and hard tissue reactions to zirconia were favorable.
MATERIALS AND METHODS: Patients were treated with prefabricated titanium implants and custom-made zirconia abutments. All-ceramic crowns were fabricated and cemented with resin cement. Clinical parameters such as Plaque Index, Sulcus Bleeding Index, peri-implant probing depth, and radiographic marginal bone loss levels were recorded, along with any biologic and mechanical complications, at baseline and up to 5 years.
RESULTS: Twelve patients with missing maxillary lateral incisors treated with a total of 23 implants were evaluated. Thirteen Straumann Narrow Neck Solid Screw implants with a diameter of 3.3 mm and 10 Astra MicroThread implants with a diameter of 3.5 mm were used. Six patients with 11 implants were treated with custom-made zirconia abutments and prefabricated metal abutments were used in the control group. Implant and abutment success at 5 years was 100%. No abutment fractures occurred. Abutment screw loosening was reported for one restoration at the 1-year recall. Mean marginal bone loss measured 0.21 mm after 5 years of functional loading.
CONCLUSION: Custom-made zirconia abutments offered sufficient stability to support all-ceramic restorations over narrow implants in anterior regions over a 5-year period. The soft and hard tissue reactions to zirconia were favorable.