MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-012-0175-3

Медицинская библиотека · Japanese journal of radiology · 2013

Clinical feasibility of pulmonary perfusion analysis using dynamic computed tomography and a gamma residue function.

Shimatani Yasuhiko, Kodani Kazuhiko, Okada Junko, Ametani Motoki, Kaminou Toshio, Ogawa Toshihide

СтатьяПеревод в очереди

Аннотация

PURPOSE: To create and determine the clinical feasibility of a model based on dynamic computed tomography (CT) and a bolus injection of iodine contrast medium for evaluation of pulmonary perfusion for healthy individuals and for patients with lung diseases.

MATERIALS AND

METHODS

We analyzed pulmonary perfusion by means of dynamic 16-row multidetector CT scanning with a gamma residue function with adding a linear component (extended gamma function model) for 20 healthy individuals and in five patients.

RESULTS

Four types of the time-attenuation curve (TAC) were identified for the peripheral lung. Although the TACs of most pixels for the peripheral lung comprised a single peak or a single-peak followed by another increase, no peak was observed for a small proportion of pixels, which either increased linearly or resulted in a delayed peak for healthy subjects. The ratios of these linearly increasing or delayed peak types of lung fields increased for pathological lungs. The analytical results for pathological cases showed that changes in lung perfusion, difficult to identify using only CT imaging, could be detected.

CONCLUSIONS

The extended gamma function model adequately evaluated pulmonary perfusion not only for normal regions, but also for structurally abnormal regions. Regional changes in perfusion could be evaluated by use of our model, and we confirmed its clinical feasibility for pulmonary perfusion analysis.

Для цитирования: Shimatani Yasuhiko, Kodani Kazuhiko, Okada Junko, Ametani Motoki, Kaminou Toshio, Ogawa Toshihide. Clinical feasibility of pulmonary perfusion analysis using dynamic computed tomography and a gamma residue function.. Japanese journal of radiology. 2013. DOI: 10.1007/s11604-012-0175-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.