DOI 10.1111/vec.70001

Медицинская библиотека · Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001) · 2025

Quality Improvement: Diagnostic Accuracy of Mainstream Versus Sidestream Capnography in Detecting Airway Intubation of Small-Bore Styleted Nasoenteric Feeding Tubes in Dogs and Cats.

Bechtold Molly A, Miller Meredith L, Fletcher Daniel J, Sumner Julia, Lopez Daniel, Hon Stephanie

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the diagnostic accuracy of sidestream and mainstream capnography to detect misplacement of small-bore, styleted nasoenteric (NE) feeding tubes into the respiratory tract of dogs and cats.

DESIGN

Prospective study from February 2020 to November 2020.

SETTING

University teaching hospital.

ANIMALS: Ten dogs and 10 cats undergoing elective surgical procedures.

INTERVENTIONS: Under general anesthesia, an NE feeding tube attached to a handheld sidestream (dogs and cats) then mainstream capnograph (dogs) was inserted into the patient's endotracheal (ET) tube. Respiratory rate, end-tidal carbon dioxide (ETCO2), and time to ETCO2 waveform were recorded.

MEASUREMENTS AND MAIN

RESULTS

Mainstream capnography failed to detect an ETCO2 reading or respiratory waveform in all dogs evaluated. In dogs and cats, sidestream capnography accurately detected ETCO2 measurement, respiratory rate, and waveform within 4 s of feeding tube insertion into the ET tube, with ETCO2 readings >35 mm Hg in all dogs and >20 mm Hg in all cats. ETCO2 readings obtained from the NE tubes were similar to but did not match those obtained by the anesthesia monitoring equipment for dogs and cats. Sidestream capnography accurately detects airway intubation with small-bore, styleted NE tubes in dogs and cats, regardless of patient size. Further studies are required to determine whether this method could be used in awake and sedated patients in real time to detect airway intubation during placement of NE tubes.

CONCLUSIONS

Sidestream capnography is able to detect misplacement of small-bore, styleted feeding tubes into the respiratory tract of dogs and cats regardless of patient size. This technique shows promise as a tool to reduce respiratory complications of feeding tube placement in veterinary patients.

Для цитирования: Bechtold Molly A, Miller Meredith L, Fletcher Daniel J, Sumner Julia, Lopez Daniel, Hon Stephanie. Quality Improvement: Diagnostic Accuracy of Mainstream Versus Sidestream Capnography in Detecting Airway Intubation of Small-Bore Styleted Nasoenteric Feeding Tubes in Dogs and Cats.. Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). 2025. DOI: 10.1111/vec.70001.