OBJECTIVES

The aims of this study were to test the magnitude of agreement between echocardiography (echo)- and cardiac magnetic resonance (CMR)-derived left atrial (LA) strain and to study their relative diagnostic performance in discriminating diastolic dysfunction (DD) and predicting atrial fibrillation (AF).

BACKGROUNDS: Peak atrial longitudinal strain (PALS) is a novel performance index. Utility of echo-quantified LA strain has yet to be prospectively tested in relation to current DD guidelines or compared to CMR.

METHODS

The study population comprised 257 post-myocardial infarction (MI) patients undergoing echo and CMR, including prospective derivation (n = 157) and clinical validation (n = 100) cohorts. DD was graded on echo using established consensus guidelines blinded to strain results.

RESULTS

PALS on both echo and CMR was nearly 2-fold lower among patients with versus no DD (p < 0.001) and was significantly different in those with mild versus no DD (p < 0.01). In contrast, LA geometric parameters including echo- and CMR-derived volumes were significantly different between advanced versus no DD groups (p < 0.001) but not between groups with mild versus no DD (all p > 0.05). Echo and CMR PALS yielded small differences irrespective of orientation and similar diagnostic performance for DD in the derivation (area under the curve [AUC]: 0.70 to 0.78) and validation (AUC: 0.75 to 0.78) cohorts. Impaired PALS on both modalities was independently associated with MI size (p < 0.001). During 4.4 ± 3.8 years of follow-up in the derivation cohort, 8% developed AF. Both 2-chamber echo- and CMR-derived PALS stratified arrhythmic risk (p = 0.004 and p = 0.02, respectively), including a 4-fold difference among patients in the lowest versus remainder of quartiles of echo-derived PALS (24% vs. 6%). Similarly, echo and CMR PALS were lower (both p < 0.05) among patients with subsequent heart failure hospitalizations.

CONCLUSIONS

Echo-derived PALS parallels results of CMR, yields incremental diagnostic utility versus LA geometry for stratifying presence and severity of DD, and improves prediction of AF and congestive heart failure after MI.

Для цитирования: Kim Jiwon, Yum Brian, Palumbo Maria C, Sultana Razia, Wright Nathaniel, Das Mukund, You Cindy, Moskowitz Chaya S, Levine Robert A, Devereux Richard B, Weinsaft Jonathan W. Left Atrial Strain Impairment Precedes Geometric Remodeling as a Marker of Post-Myocardial Infarction Diastolic Dysfunction.. JACC. Cardiovascular imaging. 2020. DOI: 10.1016/j.jcmg.2020.05.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.