A novel immunoassay for the quantization of CYFRA 21-1 in human serum.

He An, Liu Tian-Cai, Dong Zhi-Ning, Ren Zhi-Qi, Hou Jing-Yuan, Li Ming, Wu Ying-Song

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Cytokeratin 19 fragment antigen (CYFRA 21-1) is used to diagnose and monitor neoplasms. However, the main disadvantages of the currently available CYFRA 21-1 assays include heterogenous technology, being time-consuming, and having low through-put with low insensitivity. This study investigated the use of amplified luminescent proximity homogeneous immunoassay (AlphaLISA) for the quantization of CYFRA 21-1 in human serum.

METHODS

The AlphaLISA kit was developed based on AlphaScreen detection technology with two different anti-CYFRA 21-1 monoclonal antibodies. One was coated on AlphaLISA acceptor beads and the other was biotinylated. Donor beads were coated with streptavidin. The test conditions were optimized and analytical performance was studied.

RESULTS

The measurement range of AlphaLISA CYFRA 21-1 kit was 0.08-500 ng/ml. Assay detection limit was 0.08 ng/ml. The intra- and interassay coefficients of variation were 3.00-9.00% and 4.00-10.00%, respectively. There was no cross-reaction to alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), neuron-specific enolase (NSE), cancer antigen 19-9 (CA19-9), cytokeratins 8 (CK8), and cytokeratins 18 (CK18). The correlation coefficient of blood samples involved was 0.974 between CYFRA 21-1-AlphaLISA assay and a commercial electrochemiluminescence immunoassay (ECLIA) CYFRA 21-1 kit (Roche).

CONCLUSIONS

The AlphaLISA CYFRA 21-1 kit developed in this study had favorable performance characteristics for clinical application with acceptable analytical sensitivity, specificity, and accuracy.

Для цитирования: He An, Liu Tian-Cai, Dong Zhi-Ning, Ren Zhi-Qi, Hou Jing-Yuan, Li Ming, Wu Ying-Song. A novel immunoassay for the quantization of CYFRA 21-1 in human serum.. Journal of clinical laboratory analysis. 2013. DOI: 10.1002/jcla.21597.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.