MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000480012

Медицинская библиотека · Gynecologic and obstetric investigation · 2017

Two Years Follow-Up of Patients with Abnormal Uterine Bleeding after Insertion of the Levonorgestrel-Releasing Intrauterine System.

Cim Numan, Soysal Sunullah, Sayan Sena, Yildizhan Begum, Karaman Erbil, Cetin Orkun, Tolunay Harun Egemen, Yildizhan Recep

СтатьяПеревод в очереди

Аннотация

AIM: To evaluate the efficacy and safety of levonorgestrel-releasing intrauterine system (LNG-IUS) in the long-term treatment of heavy menstrual blood loss in women unrelated to intrauterine pathology.

METHODS

One hundred and six parous women aged 33-48 years with recurrent heavy menstrual bleeding (HMB) participated in this study. The women were followed up for 24 months and were assessed for intensity of bleeding both for pre- and post-insertion periods. An LNG-IUS was inserted in each patient within 7 days of the start of menstrual flow. The women were followed up at 1, 3, 6, 12, 18, and 24 months following the insertion of the intrauterine device.

RESULTS

One hundred and two women completed the follow-up period and had a significant reduction in the amount of menstrual blood loss. The LNG-IUS was well tolerated by all women. Pre-treatment of the use of the LNG-IUS, endometrial biopsy patterns for irregular proliferative endometrium and for atypical simple hyperplasia were 34/106 (32.08%) and 61/106 (57.55%) respectively and after treatment no abnormal pathologic findings were determined (p < 0.001).

CONCLUSION

Our findings indicate that the LNG-IUS is effective for significantly reducing the amount of menstrual blood loss in women with HMB.

Для цитирования: Cim Numan, Soysal Sunullah, Sayan Sena, Yildizhan Begum, Karaman Erbil, Cetin Orkun, Tolunay Harun Egemen, Yildizhan Recep. Two Years Follow-Up of Patients with Abnormal Uterine Bleeding after Insertion of the Levonorgestrel-Releasing Intrauterine System.. Gynecologic and obstetric investigation. 2017. DOI: 10.1159/000480012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.