IMPORTANCE

Anterior segment ischemia (ASI) is a rare but potentially serious complication of strabismus surgery. Indocyanine green angiography and fluorescein angiography have been used to reveal iris-filling defects for clinicians considering a patient's risk of ASI. However, both are limited by invasive and time-consuming nature and potential adverse effects. Recently, optic coherence tomography angiography (OCT-A) has been introduced and used to image iris vasculature in individuals without abnormalities.

OBJECTIVE

To determine the use of iris OCT-A for patients undergoing strabismus surgery and who are at risk for ASI.

DESIGN, SETTING, AND

PARTICIPANTS

This prospective case series study took place in an academic center. Adults undergoing strabismus surgery on at least 1 vertical muscle were prospectively recruited. The study took place from June to November 2017, and analysis began in January 2018.

INTERVENTIONS: Indocyanine green angiography and OCT-A of the iris preoperatively and 1 day postoperatively.

MAIN OUTCOMES AND MEASURES: A masked examiner evaluated all images and determined whether any filling defects were present qualitatively (lack of perfusion) and quantitatively (for OCT-A using internal software to calculate vessel density).

RESULTS

Ten eyes of 9 individuals (mean [SD] age, 63 [11] years) were included. Two individuals (22.2%) identified as Hispanic, and 7 (77.8%) identified as white. There were 6 women (66.7%). The mean preoperative vessel density (percentage of the area occupied by vessels) averaged for all quadrants decreased from 57% preoperatively to 55% postoperatively (mean difference, 2%; 95% CI, 0.4%-4.2%; P = .05). When comparing quadrants adjacent to operated muscles, the mean vessel density decreased from 56% to 53% (mean difference, 2.6%; 95% CI, 0.17%-4.8%; P = .02). In addition, OCT-A detected vascular filling defects in the quadrant adjacent to the operated muscle on the patients in whom they were present (n = 1, inferior rectus recession).

CONCLUSIONS AND RELEVANCE: In this preliminary study, OCT-A determined iris vessel filling defects when present. In addition, OCT-A gives qualitative vessel density values that can be compared preoperatively and postoperatively although the clinical relevance of small differences is not known. While only 10 eyes were evaluated, and as such generalizability of these findings cannot be determined, the results suggest that OCT-A may be a useful tool in the evaluation of patients undergoing strabismus surgery to determine whether a patient is at risk to develop ASI.

Для цитирования: Velez Federico G, Davila Juan Pablo, Diaz Andrea, Corradetti Giulia, Sarraf David, Pineles Stacy L. Association of Change in Iris Vessel Density in Optical Coherence Tomography Angiography With Anterior Segment Ischemia After Strabismus Surgery.. JAMA ophthalmology. 2018. DOI: 10.1001/jamaophthalmol.2018.2766.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.