m+Medelevator.RU
← Поиск публикаций
Endocrine · 2020

Patients with adrenal insufficiency have cardiovascular features associated with hypovolemia.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Esposito Daniela, Bobbio Emanuele, Di Fraia Rosa, Mone Pasquale, Accardo Giacomo, De Bellis Annamaria, Iorio Sergio, Esposito Katherine, Marfella Raffaele, Johannsson Gudmundur, Ragnarsson Oskar, Pasquali Daniela

Аннотация

CONTEXT: Patients with adrenal insufficiency (AI) have excess mortality and morbidity, mainly due to cardiovascular (CV) diseases. The mechanisms for this is unclear.

OBJECTIVE: To assess CV structure and function in AI patients on conventional replacement therapy and after switching to once-daily, modified-release hydrocortisone (OD-HC) in comparison with healthy matched controls.

METHODS: This was a retrospective analysis of 17 adult AI patients (11 with primary AI, 6 with secondary AI) on stable replacement with cortisone acetate [median (minimum, maximum) 33.5 (12.5-50) mg] and, if needed, fludrocortisone [0.1 (0.05-0.2) mg], and 17 healthy matched controls. Ten patients were switched to an equivalent dose of OD-HC. Data from echocardiography, 24 h Holter-ECG and 24 h blood pressure monitoring were collected at baseline and 6 months after the switch to OD-HC.

RESULTS: At baseline, AI patients had smaller left ventricular diastolic diameter (47.1 ± 4.2 vs. 51.6 ± 2.3 mm; P = 0.001) and left atrial diameter (34.9 ± 4.7 vs. 38.2 ± 2.6 cm; P = 0.018), and a higher ejection fraction (62.5 ± 6.9% vs. 56.0 ± 4.7%; P = 0.003) than controls. AI patients had lower nocturnal systolic and diastolic blood pressure than controls (108 ± 15 mmHg vs. 117 ± 8 mmHg; P = 0.038 and 65 ± 9 mmHg vs. 73 ± 7 mmHg; P = 0.008, respectively). After the switch to OD-HC, nocturnal diastolic blood pressure normalised. No significant changes were observed in echocardiographic and Holter-ECG parameters following the switch.

CONCLUSIONS: AI patients on conventional treatment display cardiovascular abnormalities that could be related to hypovolemia. Switch to OD-HC seems to have beneficial effect on blood pressure profile, but no effect on cardiovascular structure and function.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты