MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jneuroim.2021.577503

Медицинская библиотека · Journal of neuroimmunology · 2021

A case of Anti-LGi1 antibody positive autoimmune epilepsy following deep brain stimulator implantation for essential tremor.

Beer Reuben, Lehn Alex, Blum Stefan

Клинический случайСтатьяПеревод в очереди

Аннотация

We describe a 59-year-old male who developed faciobrachial dystonic seizures and serum Anti-LGi1 antibody positivity 5 weeks after subthalamic deep brain stimulation (DBS) implantation for essential tremor. Brain MRI prior to implantation was normal. Electroencephalogram was normal. A lung lesion with low PET avidity was identified and biopsied; histology was non-diagnostic. Treatment response to immunoglobulin was observed. Seizures after DBS implantation are rare, and to our knowledge not described in association with anti-LGi1 antibodies.

Для цитирования: Beer Reuben, Lehn Alex, Blum Stefan. A case of Anti-LGi1 antibody positive autoimmune epilepsy following deep brain stimulator implantation for essential tremor.. Journal of neuroimmunology. 2021. DOI: 10.1016/j.jneuroim.2021.577503.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.