MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.sleep.2013.12.013

Медицинская библиотека · Sleep medicine · 2014

Accuracy of portable polygraphy for the diagnosis of sleep apnea in multiple system atrophy.

Meissner Wassilios G, Flabeau Olivier, Perez Paul, Taillard Jacques, Marquant Fabienne, Dupouy Sandrine, Tison François, Philip Pierre, Ghorayeb Imad

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To assess the diagnostic accuracy of portable polygraphy (PG) for the detection of sleep apnea (SA) in multiple system atrophy (MSA).

METHODS

Thirty consecutive patients with probable MSA underwent PG (overnight recording of nasal flow, thoracic/abdominal movements and pulse oximetry), followed 4 weeks later by full polysomnography (PSG) (reference standard). The accuracy of PG was first assessed using the same threshold as for PSG (apnea-hypopnea index [AHI]≥5), then for all possible AHI thresholds using the area under the receiver operating characteristics (AUROC) curve. Inter-rater reliability of PG was assessed using the kappa coefficient.

RESULTS

Among 30 patients enrolled, seven were excluded for technical problems on PG or PSG and 23 were included in the main analysis. Eight out of 23 had an AHI≥5 on PSG. With the same threshold, sensitivity, specificity, positive and negative predictive values of PG for the diagnosis of SA were 87.5% (95% confidence interval: 47-99), 80% (52-96), 70% (35-93) and 92.3% (64-99), respectively. The kappa between PG raters was 0.75 (0.49-1.00) indicating good agreement. The AUROC was 0.93 (0.82-1.00). No association was found between sleep and excessive daytime sleepiness questionnaires and SA.

CONCLUSION

Portable PG seems to be valuable for ruling out SA in MSA.

Для цитирования: Meissner Wassilios G, Flabeau Olivier, Perez Paul, Taillard Jacques, Marquant Fabienne, Dupouy Sandrine, Tison François, Philip Pierre, Ghorayeb Imad. Accuracy of portable polygraphy for the diagnosis of sleep apnea in multiple system atrophy.. Sleep medicine. 2014. DOI: 10.1016/j.sleep.2013.12.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.