MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5665/sleep.1162

Медицинская библиотека · Sleep · 2011

Response of genioglossus muscle to increasing chemical drive in sleeping obstructive apnea patients.

Loewen Andrea H S, Ostrowski Michele, Laprairie John, Maturino Frances, Hanly Patrick J, Younes Magdy

СтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVES

Subjects with a collapsible upper airway must activate their pharyngeal dilators sufficiently in response to increasing chemical drive if they are to maintain airway patency without arousal from sleep. Little is known about the response of pharyngeal dilators to increasing chemical drive in these subjects. We wished to determine, in obstructive apnea patients, the response of the genioglossus to increasing chemical drive and the contribution of mechanoreceptor feedback to this response.

DESIGN

Physiological study.

SETTING

University-based sleep laboratory.

PATIENTS: 20 patients with obstructive apnea.

INTERVENTIONS: Genioglossus activity was monitored during overnight polysomnography on optimal continuous positive airway pressure (CPAP). Intermittently, inspired gases were altered to produce different levels of ventilatory stimulation. CPAP was then briefly reduced to 1.0 cm H(2)O (dial-down), inducing an obstruction.

MEASUREMENTS AND

RESULTS

Without mechanoreceptor feedback (i.e., on CPAP) the increase in genioglossus activity as ventilation increased from 6.1 ± 1.4 to 16.1 ± 4.8 L/min was modest (ΔTonic activity 0.3% ± 0.5%maximum; ΔPhasic activity 1.7% ± 3.4%maximum). Genioglossus activity increased immediately upon dial-down, reflecting mechanoreceptor feedback, but only when ventilation before dial-down exceeded a threshold value. This threshold varied among patients and, once surpassed, genioglossus activity increased briskly with further increases in chemical drive (1.1% ± 0.84%GG(MAX) per L/min increase in V(E)).

CONCLUSIONS

In sleeping obstructive apnea patients: (1) Mechanoreceptor feedback is responsible for most of the genioglossus response to chemical drive. (2) Mechanoreceptor feedback is effective only above a threshold chemical drive, which varies greatly among patients. These findings account in part for the highly variable relation between pharyngeal mechanical abnormalities and apnea severity.

Для цитирования: Loewen Andrea H S, Ostrowski Michele, Laprairie John, Maturino Frances, Hanly Patrick J, Younes Magdy. Response of genioglossus muscle to increasing chemical drive in sleeping obstructive apnea patients.. Sleep. 2011. DOI: 10.5665/sleep.1162.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.