Liang Jun, Cai Yingli, Shao Yiming
Аннотация
BACKGROUND: The early diagnosis of sepsis is hampered by the lack of reliable laboratory measures. There is growing evidence that presepsin and Mid-regional pro-adrenomedullin (MR-proADM) are promising biomarkers in the diagnosis of sepsis. This study was conducted to evaluate and compare the diagnostic value of MR-proADM and presepsin in sepsis patients.
METHODS: We searched Web of Science, PubMed, Embase, China national knowledge infrastructure, and Wanfang up to 22th July, 2022, for studies evaluating the diagnosis performance of presepsin and MR-proADM in adult sepsis patients. Risk of bias was assessed using quadas-2. Pooled sensitivity and specificity were calculated using bivariate meta-analysis. Meta-regression and subgroup analysis were used to find source of heterogeneity.
RESULTS: A total of 40 studies were eventually selected for inclusion in this meta-analysis, including 33 for presepsin and seven for MR-proADM. Presepsin had a sensitivity of 0.86 (0.82-0.90), a specificity of 0.79 (0.71-0.85), and an AUC of 0.90 (0.87-0.92). The sensitivity of MR-proADM was 0.84 (0.78-0.88), specificity was 0.86 (0.79-0.91), and AUC was 0.91 (0.88-0.93). The profile of control group, population, and standard reference may be potential sources of heterogeneity.
CONCLUSIONS: This meta-analysis demonstrated that presepsin and MR-proADM exhibited high accuracy (AUC ≥ 0.90) in the diagnosis of sepsis in adults, with MR-proADM showing significantly higher accuracy than presepsin.
METHODS: We searched Web of Science, PubMed, Embase, China national knowledge infrastructure, and Wanfang up to 22th July, 2022, for studies evaluating the diagnosis performance of presepsin and MR-proADM in adult sepsis patients. Risk of bias was assessed using quadas-2. Pooled sensitivity and specificity were calculated using bivariate meta-analysis. Meta-regression and subgroup analysis were used to find source of heterogeneity.
RESULTS: A total of 40 studies were eventually selected for inclusion in this meta-analysis, including 33 for presepsin and seven for MR-proADM. Presepsin had a sensitivity of 0.86 (0.82-0.90), a specificity of 0.79 (0.71-0.85), and an AUC of 0.90 (0.87-0.92). The sensitivity of MR-proADM was 0.84 (0.78-0.88), specificity was 0.86 (0.79-0.91), and AUC was 0.91 (0.88-0.93). The profile of control group, population, and standard reference may be potential sources of heterogeneity.