Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2016

Correlation Between Cervical Lengths Measured by Transabdominal and Transvaginal Sonography for Predicting Preterm Birth.

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cho Hyun Jin, Roh Hyun-Jin

Аннотация

OBJECTIVES: Cervical length assessment is important for predicting preterm birth. Cervical length measurement using transabdominal sonography is more comfortable for the patient but has more limitations than transvaginal sonography. Our aim was to determine whether transabdominal sonography could identify those women who should undergo transvaginal sonography for prediction of preterm birth.

METHODS: In this prospective study, women underwent cervical length measurements by transabdominal and transvaginal sonography between 20 and 29 gestational weeks and were followed until delivery. We assessed whether short cervical lengths on transabdominal sonography could predict short cervical lengths on transvaginal sonography and whether these measurements could predict preterm births (<34 gestational weeks).

RESULTS: The mean cervical lengths were not significantly different between the techniques (mean ± SD, 3.78 ± 0.82 and 3.82 ± 0.77 cm on transabdominal and transvaginal sonography, respectively; P = .09). The sensitivity of short cervical lengths (<2 cm) on transabdominal sonography for prediction of short cervical lengths on transvaginal sonography was 100%. The sensitivity, specificity, positive predictive value, negative predictive value, and relative risk of short cervical lengths (<2 cm) for predicting preterm birth were 21.4%, 98.68%, 50.00%, 95.32%, and 13.22 when using transabdominal sonography and 28.57%, 94.94%, 66.6%, 95.74%, and 17.78 when using transvaginal sonography, respectively. In an analysis that included cases with transabdominal sonography, the sensitivity of short cervical lengths for predicting preterm birth was increased.

CONCLUSIONS: Women whose cervical lengths are measurable and long on transabdominal sonography may not need transvaginal sonography. Women whose cervical lengths are unmeasurable or short (<2 or <2.5 cm) on transabdominal sonography should undergo transvaginal sonography to measure cervical lengths for prediction of preterm birth.

Предметные рубрики MeSH