[Successful endoscopic ultrasound-guided cyst drainage (EUS-CD) of pancreatic pseudocyst in the abdominal cavity to the cervical region accompanied by spontaneous rupture into the portal vein:a case study].

Takayanagi Takuya, Sekino Yusuke, Ishii Ken, Sato Shinji, Umemura Ryusuke, Uchiyama Shiori, Kanazawa Noriyoshi, Kawana Kenichi, Nagase Hajime

Клинический случайСтатьяПеревод в очереди

Аннотация

A 53-year-old man was admitted to our hospital with the complaint of neck pain and dyspnea. His blood examination revealed increased C-reactive protein and amylase levels. Enhanced computed tomography (CT) images demonstrated a retropharyngeal and a mediastinal low-density area extending to the portal area. He was diagnosed with pancreatic pseudocyst from the abdominal cavity to the cervical region accompanied by spontaneous rupture into the portal vein. Endoscopic ultrasound-guided cyst drainage (EUS-CD) of the most inferior cavity around the superior mesenteric artery was performed through the gastric wall. No adverse events were recorded during the procedure, and a near-complete resolution of his symptoms and the pseudocyst was achieved.

Для цитирования: Takayanagi Takuya, Sekino Yusuke, Ishii Ken, Sato Shinji, Umemura Ryusuke, Uchiyama Shiori, Kanazawa Noriyoshi, Kawana Kenichi, Nagase Hajime. [Successful endoscopic ultrasound-guided cyst drainage (EUS-CD) of pancreatic pseudocyst in the abdominal cavity to the cervical region accompanied by spontaneous rupture into the portal vein:a case study].. Nihon Shokakibyo Gakkai zasshi = The Japanese journal of gastro-enterology. 2018. DOI: 10.11405/nisshoshi.115.219.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.