PURPOSE: This study compared the dimensional changes between computer-aided design and computer-aided manufacturing (CAD-CAM) milled complete denture bases (CDBs) and three-dimensional (3D) printed CDBs.

MATERIALS AND

METHODS

One maxillary completely edentulous stone model was fabricated with three reference points at the incisive papilla, right molar, and left molar areas marked as X, Y, and Z, respectively. It was scanned to produce a standard tessellation language (STL) file, which was imported to a metal milling machine software to produce the metal model. This metal model was used to fabricate 30 CDBs for analysis. The CDBs were divided into three groups (n = 10 each) according to the fabrication method used as follows: Group 1, CAD-CAM milled CDBs; Group 2, 3D printed CDBs; and Group 3, conventional compression molded CDBs. The CDBs of all groups were scanned after fabrication, and the dimensional changes in each were evaluated by two methods. The first was the two-dimensional evaluation method that involved linear measurement of the distances between the reference points (X-Y, X-Z, and Y-Z) of the scanned reference cast and dentures. The second method was the 3D evaluation method that involved the superimposition of the STL files of the dentures on the STL file of the reference cast. Data were calculated and were statistically analyzed using one-way analysis of variance and Tukey's pairwise post hoc tests.

RESULTS

There was a significant difference in the dimensional accuracy between the CAD-CAM milled, 3D printed, and conventional compression molded CDBs (p < 0.05).

CONCLUSION

The dimensional accuracy of the CAD-CAM milling system in complete denture fabrication is superior to that of the compression molding and 3D printing systems.

Для цитирования: Helal Mohamed Ahmed, Abdelrahim Ramy Abdallah, Zeidan Ahmed Abd El-Latif. Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study.. Journal of prosthodontics : official journal of the American College of Prosthodontists. 2022. DOI: 10.1111/jopr.13538.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.