MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000014316

Медицинская библиотека · Medicine · 2019

Inadvertent epidural anesthesia associated with catheterization following continuous psoas compartment block in a patient with scoliosis: A Case report.

Kim Byung-Gun, Yang Chunwoo, Soh Sunghyun, Lee Kyungjoo

Клинический случайСтатьяПеревод в очереди

Аннотация

RATIONALE: Psoas compartment block (PCB) is typically performed using surface anatomical landmarks and neurostimulation for guidance. However, anatomical anomalies, such as scoliosis, make this technique unreliable, posing a challenge for the anesthesiologist when inducing regional anesthesia.

PATIENT CONCERNS: A 69-year-old woman with lumbar scoliosis scheduled for total hip arthroplasty underwent PCB with catheterization.

DIAGNOSES: Inadvertent epidural anesthesia with catheterization following PCB was diagnosed using a lumbar radiograph.

INTERVENTIONS: Due to hypotension induced by local anesthetic (LA) epidural diffusion, the patient received intravenous hydration and vasopressor. Since bilateral sensory block was noted at the T3 level, with an incomplete motor blockade in both legs, the surgery was performed under epidural anesthesia.

OUTCOMES: The patient remained hemodynamically stable throughout the duration of the surgical procedure. The surgery was uneventful and without further complications.

LESSONS: Patients with lumbar scoliosis are highly at risk of LA epidural diffusion, following PCB using traditional landmark-based approach. Other nerve-localizing technique can minimize the risk of this complication.

Для цитирования: Kim Byung-Gun, Yang Chunwoo, Soh Sunghyun, Lee Kyungjoo. Inadvertent epidural anesthesia associated with catheterization following continuous psoas compartment block in a patient with scoliosis: A Case report.. Medicine. 2019. DOI: 10.1097/md.0000000000014316.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.