MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circulationaha.107.726372

Медицинская библиотека · Circulation · 2008

Implantable cardioverter-defibrillators in tetralogy of Fallot.

Khairy Paul, Harris Louise, Landzberg Michael J, Viswanathan Sangeetha, Barlow Amanda, Gatzoulis Michael A, Fernandes Susan M, Beauchesne Luc, Therrien Judith, Chetaille Philippe, Gordon Elaine, Vonder Muhll Isabelle, Cecchin Frank

Оценочное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Tetralogy of Fallot is the most common form of congenital heart disease in implantable cardioverter-defibrillator (ICD) recipients, yet little is known about the value of ICDs in this patient population.

METHODS AND

RESULTS

We conducted a multicenter cohort study in high-risk patients with Tetralogy of Fallot to determine actuarial rates of ICD discharges, identify risk factors, and characterize ICD-related complications. A total of 121 patients (median age 33.3 years; 59.5% male) were enrolled from 11 sites and followed up for a median of 3.7 years. ICDs were implanted for primary prevention in 68 patients (56.2%) and for secondary prevention in 53 (43.8%), defined by clinical sustained ventricular tachyarrhythmia or resuscitated sudden death. Overall, 37 patients (30.6%) received at least 1 appropriate and effective ICD discharge, with a median ventricular tachyarrhythmia rate of 213 bpm. Annual actuarial rates of appropriate ICD shocks were 7.7% and 9.8% in primary and secondary prevention, respectively (P=0.11). A higher left ventricular end-diastolic pressure (hazard ratio 1.3 per mm Hg, P=0.004) and nonsustained ventricular tachycardia (hazard ratio 3.7, P=0.023) independently predicted appropriate ICD shocks in primary prevention. Inappropriate shocks occurred in 5.8% of patients yearly. Additionally, 36 patients (29.8%) experienced complications, of which 6 (5.0%) were acute, 25 (20.7%) were late lead-related, and 7 (5.8%) were late generator-related complications. Nine patients died during follow-up, which corresponds to an actuarial annual mortality rate of 2.2%, which did not differ between the primary and secondary prevention groups.

CONCLUSIONS

Patients with tetralogy of Fallot and ICDs for primary and secondary prevention experience high rates of appropriate and effective shocks; however, inappropriate shocks and late lead-related complications are common.

Для цитирования: Khairy Paul, Harris Louise, Landzberg Michael J, Viswanathan Sangeetha, Barlow Amanda, Gatzoulis Michael A, Fernandes Susan M, Beauchesne Luc, Therrien Judith, Chetaille Philippe, Gordon Elaine, Vonder Muhll Isabelle, Cecchin Frank. Implantable cardioverter-defibrillators in tetralogy of Fallot.. Circulation. 2008. DOI: 10.1161/circulationaha.107.726372.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.