Vascular and endovascular surgery · 2018
Snorkel Technique for Inferior Mesenteric Artery During Endovascular Repair of Abdominal Aortic Aneurysm.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ertugay Serkan, Daylan Ahmet, Bozkaya Halil, Oğuz Emrah, Apaydın Anıl, Parıldar Mustafa, Posacıoğlu Hakan
Аннотация
PURPOSE: The snorkel technique is commonly used to preserve renal arteries in juxta renal aneurysm during endovascular repair. Herein, we present a patient who underwent bifurcated endograft implantation with snorkel technique for inferior mesenteric artery (IMA) in order to preserve the major source of bowel circulation.
CASE REPORT: A 69-year-old male patient was diagnosed with abdominal aortic aneurysm. His history revealed that he had bowel resection due to a car accident 30 years ago. In addition, he was given relaparotomy 4 times due to intestinal complications. Computed tomography showed fusiform aneurysm with a maximal diameter of 60 mm and chronical occlusion of the superior mesenteric artery. Inferior mesenteric artery was found to be hypertrophic. During EVAR, 6 mm × 10 cm covered VIABAHN Endoprosthesis (Gore Medical) was implanted to the IMA over a 0.018 guidewire via puncture of the left axillary artery. Initially, the main body of the aortic stent-graft (Gore C3, size 23-14-16) was implanted to the infra renal segment of the aorta (below the renal arteries and the orifice using VIABAHN) via the right femoral artery. Next, the contralateral leg (Gore, 14-12-00) was implanted. Computed tomography was examined at 1- and 32-month postoperatively, and no endoleak or patency of IMA stent was detected.
CONCLUSION: In this case of IMA-dependent circulation of the intestinal system, the protection of IMA via snorkel technique was successful.
CASE REPORT: A 69-year-old male patient was diagnosed with abdominal aortic aneurysm. His history revealed that he had bowel resection due to a car accident 30 years ago. In addition, he was given relaparotomy 4 times due to intestinal complications. Computed tomography showed fusiform aneurysm with a maximal diameter of 60 mm and chronical occlusion of the superior mesenteric artery. Inferior mesenteric artery was found to be hypertrophic. During EVAR, 6 mm × 10 cm covered VIABAHN Endoprosthesis (Gore Medical) was implanted to the IMA over a 0.018 guidewire via puncture of the left axillary artery. Initially, the main body of the aortic stent-graft (Gore C3, size 23-14-16) was implanted to the infra renal segment of the aorta (below the renal arteries and the orifice using VIABAHN) via the right femoral artery. Next, the contralateral leg (Gore, 14-12-00) was implanted. Computed tomography was examined at 1- and 32-month postoperatively, and no endoleak or patency of IMA stent was detected.
CONCLUSION: In this case of IMA-dependent circulation of the intestinal system, the protection of IMA via snorkel technique was successful.