BACKGROUND

Multiple randomized clinical trials have demonstrated that drug eluting stents can significantly reduce the rates of restenosis and subsequent adverse events across lesion and patient. We investigated the medium term clinical efficacy and safety of Firebird sirolimus eluting stent (SES) in coronary artery disease.

METHODS

The sample was 509 consecutive patients with coronary artery disease (CAD) who were treated by Firebird SES and finished three-year clinical follow-up. The occurrences of major adverse cardiac events (MACE) and Academic Research Consortium defined stent thrombosis (ST) were evaluated in patients with and without diabetes mellitus.

RESULTS

Three hundred and thirty three patients (65.4%) were treated by Firebird SES by off label indications. Angiographic success was achieved in 98.3% of the lesions. MACE and target vessel revascularization rates at 6-month, 1 year's and 3 years' clinical follow-up were 2.4% and 1.4%, 4.1% and 2.8%, 7.9% and 5.1%, respectively. The cumulative 3-year MACE free survival rate was 92.1%. After 3 years, DM patients had significantly higher rates of MACE (13.7% vs 6.4%, P < 0.05) and TVR (9.8% vs 4.0%, P < 0.05) and the cumulative MACE free survival rate was very significantly lower in the DM group (86.4% vs 93.6%, P < 0.05). ST occurred in 7 patients (1.4%) at the end of 3 years' follow-up, 5 of them had definite ST with 4 cases presenting with myocardial reinfarction and 1 with unstable angina, the other 2 with probable ST had reinfarction in the stented coronary territory without angiographic follow-up. There was no difference in occurrence of ST between off label (1.5%) and on label groups (1.1%, P = 0.07).

CONCLUSIONS

In daily practice, about 2/3 of patients were treated by Firebird SES by off label indications. Medium term clinical follow-up of 3 years indicated CAD patients treated by Firebird SES had a low MACE and acceptable ST rate. DM patients had higher rates of adverse events and than non DM.

Для цитирования: Zhang Qi, Xu Bo, Yang Yue-Jin, Qiao Shu-Bin, Zhang Rui-Yan, Zhang Jian-Sheng, Hu Jian, Qin Xue-Wen, Chen Ji-Lin, Shen Wei-Feng, Gao Run-Lin. Long-term efficacy and safety of Chinese made sirolimus eluting stents: results, including off label usage, from two centres over three years.. Chinese medical journal. 2008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.