MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8175.2008.00655.x

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2008

"Tardus and parvus" phenomenon in upper limb arteries for identifying subclavian arterial stenosis.

Duan Yun-You, Yuan Li-Jun, Ding Kang, Liu Xi, Lv Fa-Qin, Cao Tie-Sheng

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The detection of subclavian artery (SCA) stenosis or occlusion is important, and an easy and accurate noninvasive screening method is needed.

METHODS

Pulsed Doppler spectra of bilateral SCA, vertebral arteries, axillary arteries, and brachial arteries were recorded and analyzed both in patients with SCA stenosis and healthy subjects.

RESULTS

Thirty-five patients showed SCA stenosis less than 80% (mean: 72 +/- 14%; Vmax: 450.1 +/- 101.5 cm/sec) and seven patients demonstrated one-side SCA occlusion. The Vmax, systolic acceleration (SA) and resistance index (RI) were much lower (parvus) while the acceleration time (AT) was much longer (tardus) in axillary and brachial arteries on the ipsilateral than those both on the contralateral and the control group (Axillary artery: Vmax: 31.3 +/- 11.8 vs. 62.0 +/- 24.1 and 85.8 +/- 14.3 cm/sec, P < 0.01; SA: 2.0 +/- 1.0 vs. 6.8 +/- 4.9 and 9.6 +/- 2.0 m/sec(2), P < 0.05; RI: 0.8 +/- 0.1 vs. 1.1 +/- 0.4 and 1.1 +/- 0.3, P < 0.01; AT: 141 +/- 34 vs. 86 +/- 26 and 76 +/- 9 ms, P < 0.01. Brachial artery: Vmax: 47.5 +/- 25.2 vs. 76.7 +/- 37.6 and 84.6 +/- 14.2 cm/sec, P < 0.05; SA: 3.1 +/- 2.1 vs. 9.1 +/- 5.2 and 10.1 +/- 3.5 m/sec(2), P < 0.01; RI: 1.0 +/- 0.1 vs. 1.2 +/- 0.1 and 1.2 +/- 0.1, P < 0.01; AT: 155 +/- 31 vs. 86 +/- 19 and 78 +/- 12ms, P < 0.01).

CONCLUSIONS

The "tardus and parvus" phenomenon in ipsilateral axillary and brachial arteries could be employed as an alternative method and a shortcut for detection of the SCA stenosis or occlusion.

Для цитирования: Duan Yun-You, Yuan Li-Jun, Ding Kang, Liu Xi, Lv Fa-Qin, Cao Tie-Sheng. "Tardus and parvus" phenomenon in upper limb arteries for identifying subclavian arterial stenosis.. Echocardiography (Mount Kisco, N.Y.). 2008. DOI: 10.1111/j.1540-8175.2008.00655.x.