MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fmicb.2026.1708044

Медицинская библиотека · Frontiers in microbiology · 2026

Development and validation of a Vero cell DNA standard for residual DNA measurement suitable for quantitative PCR method.

Zhao Danhua, Wang Yunpeng, Wu Xiaohong, Shi Leitai, Li Jia, Li Yuhua, Cao Shouchun

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The fluorescence quantitative PCR method for the detection of Vero cell residual DNA in human rabies vaccine urgently needs a national standard for Vero cell DNA quantification.

METHODS

Briefly, the genomic DNA of Vero cells was extracted, diluted to 100 μg/ml, and divided into 0.1-ml aliquots in sterile screw cap tubes. After DNA preparation, concentration calibration, applicability, and stability verification were carried out by multiple laboratories.

RESULTS

The concentration of the national standard for Vero cell DNA quantification (limited qPCR method) determined from this collaborative study was 107 ± 6 μg/mL, and the DNA purity (OD260/OD280) was 1.83. This standard is only suitable for the qPCR method, which has an average amplification efficiency of 92%. After accelerated degradation at 37 °C from 1 to 4 weeks, the standard showed amplification curves similar to those stored at -70 °C, with no significant difference in amplification efficiency, showing good stability.

CONCLUSION

This study successfully developed a national standard for Vero cell DNA quantification using the quantitative fluorescence PCR method, which has significant application potential for standardizing Vero cell DNA residue detection in human rabies vaccines.

Для цитирования: Zhao Danhua, Wang Yunpeng, Wu Xiaohong, Shi Leitai, Li Jia, Li Yuhua, Cao Shouchun. Development and validation of a Vero cell DNA standard for residual DNA measurement suitable for quantitative PCR method.. Frontiers in microbiology. 2026. DOI: 10.3389/fmicb.2026.1708044.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.