Case Series of Ventriculoatrial Shunt placement in Hybrid Room: Reassessment of Ventriculoatrial Shunt.

Kim Young Ha, Lee Sang Weon, Kim Dong Hyun, Lee Chi Hyung, Kim Chang Hyeun, Sung Soon Ki, Son Dong Wuk, Song Geun Sung

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Ventriculoatrial shunt (VAS) remains an alternate option for treatment of hydrocephalus in patients with ventriculoperitoneal shunt (VPS) failure. Unfamiliar anatomy for a neurosurgeon has resulted in the VAS falling out of favor as a treatment option. However, there are unsatisfactory reports on the long-term result of VPS, and VAS has been recently re-evaluated. We are to report the simple way to do the VAS using a peel-away sheath in a hybrid operation room.

METHODS

A jugular vein path was drawn by ultrasound, a small incision was made above the clavicle, and a shunt catheter was tunneled into it. The jugular vein was punctured beside the tunneled catheter with a Seldinger needle under ultrasound guidance. A flexible guide wire was introduced into the vein and 6-Fr peel-away sheath was advanced into the vein along the wire. Under fluoroscopic guidance, the catheter was cut to position approximately mid-level in the atrium. After the guide wire was removed, the distal shunt catheter was passed down. After confirming proper position of the distal catheter under the fluoroscope, the catheter-guiding sheath was pulled out as a peeling-away manner. We performed this surgical procedures in 5 cases.

RESULTS

All the procedures of the VAS using a peel-away sheath were performed in a hybrid operation room Of 5 patients, 3 patients had the distal catheter failures in the peritoneal cavity and 2 patients had shunt A distal catheter was successfully indwelling in all the cases without any difficulties. After the surgery, neither shunt infection nor thromboembolic event happened.

CONCLUSION

VAS using fluoroscopy and a peel-away sheath is a good alternative option for hydrocephalus patients with shunt failure related to peritoneal cavity complications.

Для цитирования: Kim Young Ha, Lee Sang Weon, Kim Dong Hyun, Lee Chi Hyung, Kim Chang Hyeun, Sung Soon Ki, Son Dong Wuk, Song Geun Sung. Case Series of Ventriculoatrial Shunt placement in Hybrid Room: Reassessment of Ventriculoatrial Shunt.. Korean journal of neurotrauma. 2020. DOI: 10.13004/kjnt.2020.16.e46.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.