MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2013.08.036

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2013

The incidence of complications after posterior hindfoot endoscopy.

Donnenwerth Michael P, Roukis Thomas S

СтатьяПоддержка исследования: вне правительства СШАСистематический обзорПеревод в очереди

Аннотация

PURPOSE: The purpose of this systematic review was to determine the incidence of complications after posterior hindfoot endoscopy.

METHODS

Ovid/Medline and Google Scholar were systematically searched for pertinent references to be included. In addition, we hand-searched common American and European orthopaedic and podiatric surgical journals for relevant articles. Articles considered for inclusion were published in peer-reviewed journals, described complications after posterior hindfoot endoscopy using a standard 2-portal technique, and involved 25 or more patients treated.

RESULTS

We identified 335 potentially relevant publications, of which 5 met our inclusion criteria. A total of 452 ankles (452 patients) were included in this study. Overall, 17 complications (3.8%) occurred, with only 8 (1.8%) requiring additional treatment or operative intervention.

CONCLUSIONS

The endoscopic approach for the treatment of hindfoot and ankle pathology is safe with a low incidence of complications. However, additional studies with prospective designs should be undertaken to determine the long-term patient outcomes using validated scoring systems.

LEVEL OF EVIDENCE: Level IV, systematic review of Level III and IV studies.

Для цитирования: Donnenwerth Michael P, Roukis Thomas S. The incidence of complications after posterior hindfoot endoscopy.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2013. DOI: 10.1016/j.arthro.2013.08.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.