m+Medelevator.RU
← Поиск публикаций
Heart rhythm · 2024

Artificial intelligence-adjudicated spatiotemporal dispersion: A patient-unique fingerprint of persistent atrial fibrillation.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Seitz Julien, Mohr Durdez Théophile, Lotteau Sabine, Bars Clément, Pisapia André, Gitenay Edouard, Monteau Jacques, Reist Mélanie, Serdi Meryem, Dayot Amélie, Bremondy Michel, Benadel Mohamed, Siame Sabrina, Appetiti Anthony, Milpied Paola, Kalifa Jérôme

Аннотация

BACKGROUND: Spatiotemporal dispersion-guided ablation is a tailored approach for patients in persistent atrial fibrillation (PsAF). The characterization of dispersion extent and distribution and its association with common clinical descriptors of PsAF patients has not been studied.

OBJECTIVES: Artificial intelligence-adjudicated dispersion extent and distribution (AI-DED) was obtained with a machine/deep learning classifier (VX1 Software, Volta Medical) in PsAF patients undergoing ablation. The purpose of this study was to test the hypothesis that AI-DED is unique to each patient and independent of common procedural and clinical parameters.

METHODS: In a subanalysis of the Ev-AIFib study (NCT03434964), spatiotemporal dispersion maps were built with VX1 software in 78 consecutive persistent and long-standing PsAF patients. AI-DED was quantified using 2 distinct approaches (visual regional characterization or automated global quantification of AI-DED).

RESULTS: AI-DED paired-subregion Euclidean distance measurements between 78 patients (average distance 5.07 ± 0.60; min 2.23; max 9.75) demonstrate that AI-DED is a patient-unique characteristic of PsAF. Importantly, both AF type and AF history do not correlate with AI-DED levels (R2 = 0.006, P = .53; and R2 = 0.03, P = .25, respectively). The most extensive AI-DED levels are not associated with poorer procedural (83%, 81%, and 83% of AF termination in low, medium, and high dispersion groups, respectively; P = .954) and long-term (88%, 75%, and 91% of freedom from AF/atrial tachycardia after multiple procedures; P = .517) outcomes.

CONCLUSION: The atrial distribution and extent of multipolar electrogram spatiotemporal dispersion follow a nonrandom, albeit patient-unique, distribution in PsAF patients. AI-DED may represent a procedure-implementable fingerprint of the PsAF substrate.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты