DOI 10.1161/circinterventions.121.011778
Diffusion of Percutaneous Ventricular Assist Devices in US Markets.
Аннотация
BACKGROUND
Percutaneous ventricular assist devices (PVADs) have been replacing intra-aortic balloon pumps for hemodynamic support during percutaneous coronary intervention (PCI), even though data supporting a benefit for hard clinical end points remain limited. We evaluated diffusion of PVADs across US markets and examined the association of market utilization of PVAD with mortality and cost.
METHODS
Using the 2013 to 2019 Medicare data, we identified all patients aged ≥65 years who underwent PCI with either a PVAD or intra-aortic balloon pump. We used hospital referral region to define regional health care markets and categorized them in quartiles based on the proportional use of PVADs during PCI. Multilevel models were constructed to determine the association of patient, hospital, and market factors with utilization of PVADs and the association of PVAD utilization with 30-day mortality and cost.
RESULTS
A total of 79 176 patients underwent PCI with either intra-aortic balloon pump (47 514 [60.0%]) or PVAD (31 662 [40.0%]). The proportion of PCI procedures with PVAD increased over time (17% in 2013 to 57% in 2019; P for trend, <0.001), such that PVADs overtook intra-aortic balloon pump for hemodynamic support during PCI in 2018. There was a large variation in PVAD utilization across markets (range, 0%-85%), which remained unchanged after adjustment of patient characteristics (median odds ratio, 2.05 [95% CI, 1.91-2.17]). The presence of acute myocardial infarction, cardiogenic shock, and emergent status was associated with a 45% to 50% lower odds of PVAD use suggesting that PVADs were less likely to be used in the sickest patients. Greater utilization of PVAD at the market level was not associated with lower risk mortality but was associated with higher cost.
CONCLUSIONS
Although utilization of PVADs for PCI continues to increase, there is large variation in PVAD utilization across markets. Greater market utilization of PVADs was not associated with lower mortality but was associated with higher cost.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.