Outcome following high-dose methotrexate in pregnancies misdiagnosed as ectopic.

Nurmohamed Laila, Moretti Myla E, Schechter Tal, Einarson Adrienne, Johnson Diana, Lavigne Sharon V, Erebara Aida, Koren Gideon, Finkelstein Yaron

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective of this study was to report the outcomes of intrauterine pregnancies misdiagnosed as ectopic and exposed to methotrexate, a major teratogen.

STUDY

DESIGN

We report the outcomes of all subjects who sought consultation after exposure to high-dose methotrexate to induce abortion in presumed ectopic pregnancies, which were later identified as viable intrauterine pregnancies by 3 North American Teratology Information Services between 2002 and 2010.

RESULTS

Eight women with normal, desired pregnancies were administered high-dose methotrexate in the first trimester because of presumed, misdiagnosed ectopic pregnancies. All pregnancies resulted in catastrophic outcomes. Two pregnancies resulted in severely malformed newborns with methotrexate embryopathy; 3 women miscarried shortly after exposure, and in 3 the erroneous diagnosis led the physicians to advise and perform surgical termination.

CONCLUSION

Erroneous diagnosis of intrauterine pregnancies as ectopic with subsequent first-trimester exposure to methotrexate may result in the birth of severely malformed babies or fetal demise.

Для цитирования: Nurmohamed Laila, Moretti Myla E, Schechter Tal, Einarson Adrienne, Johnson Diana, Lavigne Sharon V, Erebara Aida, Koren Gideon, Finkelstein Yaron. Outcome following high-dose methotrexate in pregnancies misdiagnosed as ectopic.. American journal of obstetrics and gynecology. 2011. DOI: 10.1016/j.ajog.2011.07.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.