Piratvisuth Teerha, Hou Jinlin, Tanwandee Tawesak, Berg Thomas, Vogel Arndt, Trojan Jörg, De Toni Enrico N, Kudo Masatoshi, Eiblmaier Anja, Klein Hanns-Georg, Hegel Johannes Kolja, Madin Kairat, Kroeniger Konstantin, Sharma Ashish, Chan Henry L Y

Аннотация

BACKGROUND: Alpha-fetoprotein (AFP) and des-gamma carboxyprothrombin (DCP), also known as protein induced by vitamin K absence-II (PIVKA-II [DCP]) are biomarkers for HCC with limited diagnostic value when used in isolation. The novel GAAD algorithm is an in vitro diagnostic combining PIVKA-II (DCP) and AFP measurements, age, and gender (biological sex) to generate a semi-quantitative result. We conducted prospective studies to develop, implement, and clinically validate the GAAD algorithm for differentiating HCC (early and all-stage) and benign chronic liver disease (CLD), across disease stages and etiologies.

METHODS: Patients aged ≥18 years with HCC or CLD were prospectively enrolled internationally into algorithm development [n = 1084; 309 HCC cases (40.7% early-stage) and 736 controls] and clinical validation studies [n = 877; 366 HCC cases (47.6% early-stage) and 303 controls]. Serum samples were analyzed on a cobas® e 601 analyzer. Performance was assessed using receiver operating characteristic curve analyses to calculate AUC.

RESULTS: For algorithm development, AUC for differentiation between early-stage HCC and CLD was 90.7%, 84.4%, and 77.2% for GAAD, AFP, and PIVKA-II, respectively. The sensitivity of GAAD for the detection of early-stage HCC was 71.8% with 90.0% specificity. Similar results were shown in the clinical validation study; AUC for differentiation between early-stage HCC and CLD was 91.4% with 70.1% sensitivity and 93.7% specificity. GAAD also showed strong specificity, with a lower rate of false positives regardless of disease stage, etiology, or region.

CONCLUSIONS: The GAAD algorithm significantly improves early-stage HCC detection for patients with CLD undergoing HCC surveillance. Further phase III and IV studies are warranted to assess the utility of incorporating the algorithm into clinical practice.