m+Medelevator.RU
← Поиск публикаций
Journal of veterinary internal medicine · 2007

Transthoracic echocardiographic measurement of patent ductus arteriosus in dogs.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schneider Matthias, Hildebrandt Nicolai, Schweigl Tatjana, Wehner Martin

Аннотация

BACKGROUND: Patent ductus arteriosus (PDA) size and morphology influence the selection of the kind and the size of the embolization device used to effect shunt closure.

HYPOTHESIS: That echocardiographic measurement of PDA in dogs is accurate.

ANIMALS: Forty-five client-owned dogs with PDA.

METHODS: Prospective observational study. Echocardiographic and angiographic data were compared.

RESULTS: Measurement of the ductus in color Doppler echocardiography (CD-E) and 2-dimensional echocardiography (2D-E) was achieved from left parasternal views in 43 of 45 unsedated dogs (96%). In these 43 dogs, the angiographic minimal PDA diameter was 3.72 +/- 1.59 mm, and the diameter of the PDA ampulla was 8.46 +/- 3.01 mm. The CD-E minimal PDA diameter ranged from 2.3 to 9.5 mm (median, 4.0 mm). There was a significant mean difference to the angiographic measurements (1.15 +/- 0.95 mm; P < .0001). An agreement in a 1-mm range was found in 21 of 43 dogs (48%). The 2D-E minimal PDA diameter was 3.73 +/- 1.78 mm, and the mean difference to the angiographic measurements was not significant (0.00 +/- 0.72 mm; P = .98). An agreement in a 1-mm range was found in 31 of 43 dogs (72%). The 2D-E measurement of the PDA ampulla revealed a significant mean difference to the angiographic data (1.95 +/- 2.43 mm, P < .0001). An agreement in a 2-mm range was found in 21 of 43 dogs (49%).

CONCLUSIONS AND CLINICAL IMPORTANCE: The 2D-E from the left cranial parasternal view is an excellent noninvasive method to estimate the PDA minimal diameter before doing catheter intervention.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты