MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm14124137

Медицинская библиотека · Journal of clinical medicine · 2025

Transcutaneous CO2 Measurement in an Adult Long-Term Ventilation (LTV) Service.

Ong Wei Hann, Ireland Peter, Ho Ching Khai, Fowkes Ross, Madhu Yamuna, Davidson Richard, Kaiser Katie, George Kathy, Rodger Jane, Armstrong Alison, Messer Ben, Tedd Hilary, Lane Nicholas, De Soyza Anthony

СтатьяПеревод в очереди

Аннотация

Background

Transcutaneous CO2 (TcCO2) measurement is widely used in the diagnosis and monitoring of ventilatory failure. Robust data on the success rates of measurement is scant. We aimed to discern the factors affecting the success rate of TcCO2 measurement in a regional LTV service.

Methods

Patients undergoing TcCO2 measurement between October 2019 and January 2022 were identified retrospectively. Notes were analysed for basic demographics, indications for TcCO2 measurement, measurement outcome, device used (Radiometer TCM5 or Sentec, based on availability), setup (self, carer, or clinician), inpatient or domiciliary study, and number of TcCO2 measurement attempts occurred. Statistical comparisons were made by Fisher's exact test.

Results

We identified 435 recording events on 288 patients, mean age of 53, and 56% were males. A total of 189 (66%) had a neuromuscular disorder (NMD). The commonest indications for TcCO2 measurement were 'assessing ventilatory failure' (43%) in treatment-naïve patients and 'adequacy of ventilation therapy due to persistent symptoms' (26%) in those established on LTV. Over 80% of our recording events were applied by patients or their carers. Overall, TCM5 devices had statistically higher successful recording rates (197/268, 73.5%) than Sentec (100/165, 60.6%) [p = 0.0056]. In domiciliary studies, TCM5's success rate of 187/253 (73.9%) versus Sentec's 94/154 (61.0%) was significantly better [p = 0.0079]. The success rate of each measurement attempt ranged between 62.9 and 67.0%, with up to three attempts on each subject.

Conclusions

Home TcCO2 is helpful in managing those with respiratory failure. Repeating tests after initial failure of recording is worthwhile. There may be differences in performance across devices which warrants further study.

Для цитирования: Ong Wei Hann, Ireland Peter, Ho Ching Khai, Fowkes Ross, Madhu Yamuna, Davidson Richard, Kaiser Katie, George Kathy, Rodger Jane, Armstrong Alison, Messer Ben, Tedd Hilary, Lane Nicholas, De Soyza Anthony. Transcutaneous CO2 Measurement in an Adult Long-Term Ventilation (LTV) Service.. Journal of clinical medicine. 2025. DOI: 10.3390/jcm14124137.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.