DOI 10.1016/s1067-2516(02)80054-0
Ilizarov ring fixator for a difficult case of ankle syndesmosis disruption.
Аннотация
Syndesmotic stabilization is recommended for tibiofibular diastasis, a Maisonneuve fracture, or syndesmotic instability after fixation of distal tibia-fibula fractures. In the case presented, a syndesmotic stabilization was performed with a screw inserted 2 cm above the tibiotalar joint Subsequent failure occurred due to the weight of the patient and a lack of compliance with the necessary nonweight bearing protocol. The Ilizarov frame was used to reduce and maintain a stable syndesmosis with a simple two-ring construct which allowed the patient to bear weight on the injured limb while his syndesmosis healed. This is not recommend as a routine method of treatment, but is presented as an extended indication of the Ilizarov frame for difficult cases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.