[Minimally invasive anterior transarticular screw fixation and fusion for atlantoaxial instability].
Аннотация
OBJECTIVE
To investigate the clinical results and complications of minimally invasive anterior transarticular screw fixation and fusion for atlantoaxial instability.
METHODS
Between May 2007 and December 2010, 13 patients with atlantoaxial instability were treated with minimally invasive anterior transarticular screw fixation and fusion under endoscope. There were 11 males and 2 females, aged 17-61 years (mean, 41.3 years). The time between injury and operation was 5-14 days (mean, 7.4 days). All cases included 6 patients with Jefferson fracture, 5 with odontoid fracture, and 2 with os odontoideum. According to Frankel classification of nerve functions, 2 cases were rated as grade D and 11 cases as graed E. The operation time, intra-operative blood loss, radiation exposure time, and complications were recorded and analyzed. The stability was observed by X-ray films. The clinical outcome was assessed using the Frankel scale, and the fusion rates were determined by CT scan three-dimensional reconstruction at last follow-up.
RESULTS
The mean operation time was 124 minutes (range, 95-156 minutes); the mean intra-operative blood loss was 65 mL (range, 30-105 mL); and the mean radiation exposure time was 41 seconds (range, 30-64 seconds). Thirteen patients were followed up 12-47 months (mean, 25.9 months). No blood vessel and nerve injuries or internal fixator failure occurred. The bone fusion time was 6 months, and the dynamic cervical radiography showed no instability occured. At last follow-up, the neurological function was grade E in all patients. The fusion rate was 84.6% (11/13). No continuous bone bridge was seen in the joint space of 2 patients, but they achieved stability.
CONCLUSION
Minimally invasive anterior transarticular screw fixation and fusion is a safe and effective procedure for treatment of atlantoaxial instability.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.