Balloon Versus Self-Expandable Valve for the Treatment of Bicuspid Aortic Valve Stenosis: Insights From the BEAT International Collaborative Registrys.
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Mangieri Antonio, Tchetchè Didier, Kim Won-Keun, Pagnesi Matteo, Sinning Jean-Malte, Landes Uri, Kornowski Ran, De Backer Ole, Nickenig Georg, Ielasi Alfonso, De Biase Chiara, Søndergaard Lars, De Marco Federico, Montorfano Matteo, Chiarito Mauro, Regazzoli Damiano, Stefanini Giulio, Presbitero Patrizia, Toggweiler Stefan, Tamburino Corrado, Immè Sebastiano, Tarantini Giuseppe, Sievert Horst, Schäfer Ulrich, Kempfert Jörg, Wöehrle Jochen, Gallo Francesco, Laricchia Alessandra, Latib Azeem, Giannini Francesco, Colombo Antonio
Аннотация
METHODS: The BEAT (balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis) registry included 353 consecutive patients who underwent transcatheter aortic valve implantation using new-generation Evolut R/PRO or Sapien 3 valves in bicuspid aortic valve.
RESULTS: A total of 353 patients (n=242 [68.6%] treated with Sapien 3 and n=111 [68.6%] treated with Evolut R (n=70)/PRO [n=41]) were included. Mean age was 77.8±8.3 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality was 4.4±3.3%. Valve Academic Research Consortium-2 device success was similar between Sapien 3 and Evolut R/PRO (85.6% versus 87.2%; P=0.68). In the Sapien 3 group, 4 patients experienced annular rupture whereas this complication did not occur in the Evolut R/PRO group. After propensity score matching, Valve Academic Research Consortium-2 device success was similar between both groups (Sapien 3=85.7% versus Evolut R/Pro=84.4%; P=0.821). Both in the overall and in the matched population, no differences in the rate of permanent pacemaker implant were observed. At 1-year follow-up, the rate of overall death and cardiovascular death were similar between the 2 groups. In the unmatched population, the 1-year echocardiographic follow-up demonstrated similar rate of moderate-to-severe paravalvular aortic regurgitation (Evolut R/PRO 10.5% versus Sapien 3 4.2%, P=0.077); however, after propensity matching, the rate of moderate-to-severe paravalvular leak became significantly higher among patients treated with self-expandable valves (9.3% versus 0%; P=0.043).
CONCLUSIONS: Our study confirms the feasibility of both Sapien 3 and Evolut R/PRO implantation in bicuspid aortic valve anatomy; a higher rate of moderate-severe paravalvular aortic regurgitation was observed in the Evolut R/PRO group at 1-year follow-up in the matched cohort, although patients treated with balloon-expandable valve had a higher rate of annular rupture.