Nakagawa Ryunosuke, Nohara Takahiro, Kano Hiroshi, Makino Tomoyuki, Naito Renato, Iwamoto Hiroaki, Yaegashi Hiroshi, Kawaguchi Shohei, Shigehara Kazuyoshi, Izumi Kouji, Mizokami Atsushi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Photodynamic diagnosis-assisted transurethral resection of bladder tumor (PDD-TURBT) for nonmuscle-invasive bladder cancer is superior to conventional white-light TURBT for cancer detection. However, when performing PDD-TURBT, cystoscopy findings vary depending on the quality of the endoscopic equipment. In this study, we compared the effects of different types of endoscopic equipment on postoperative outcomes.

METHODS

Patients who underwent their first PDD-TURBT at our clinic were selected. Patients on whom PDD-TURBT was performed using endoscopic equipment A were sorted into Group A, and patients on whom PDD-TURBT was performed using equipment S were sorted into Group S. The characteristics, recurrence-free survival (RFS), and recurrence frequency of these patients were retrospectively investigated and compared. The prognostic factors for RFS were also analyzed.

RESULTS

A total of 49 patients were included in Group A and 46 in Group S. In Group S, a higher detection rate (8.2% vs. 30.4 %, p < 0.01) of carcinoma in situ (CIS) was noted. RFS tended to be better in Group S (HR 0.63, p = 0.15). The frequency of recurrence also tended to be lower in Group S (4.92 vs. 3.66 per 10,000 person-days, p = 0.08). Furthermore, CIS (HR 0.30, p = 0.04) and Bacillus Calmette-Guerin therapy (HR: 0.26, p = 0.01) were significant favorable prognostic factors for RFS.

CONCLUSION

The quality of the endoscopic equipment may influence postoperative recurrence after PDD-TURBT. Higher-quality endoscopic instruments have superior CIS detection capabilities, which can lead to improvements in postoperative outcomes with the appropriate selection of postoperative adjuvant therapy.

Для цитирования: Nakagawa Ryunosuke, Nohara Takahiro, Kano Hiroshi, Makino Tomoyuki, Naito Renato, Iwamoto Hiroaki, Yaegashi Hiroshi, Kawaguchi Shohei, Shigehara Kazuyoshi, Izumi Kouji, Mizokami Atsushi. Does the quality of endoscopic equipment influence the recurrence rate after photodynamic diagnosis-assisted transurethral resection of bladder tumor?. Photodiagnosis and photodynamic therapy. 2024. DOI: 10.1016/j.pdpdt.2024.104023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.