m+Medelevator.RU
← Поиск публикаций
Transplantation proceedings · 2009

Value of stress myocardial perfusion scanning in diagnosis of severe coronary artery disease in liver transplantation candidates.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Aydinalp A, Bal U, Atar I, Ertan C, Aktaş A, Yildirir A, Ozin B, Mudderisoglu H, Haberal M

Аннотация

BACKGROUND: The significant potential for perioperative and late cardiovascular complications makes careful preoperative cardiac risk assessment imperative in liver transplantation candidates.

OBJECTIVE: To determine the sensitivity and specificity of myocardial perfusion scanning for detection of coronary artery disease (CAD) in liver transplantation candidates.

PATIENTS AND METHODS: We prospectively evaluated 93 liver transplantation candidates. Patients with known CAD were excluded. All patients, regardless of symptoms and risk factors, underwent myocardial perfusion scanning and coronary angiography.

RESULTS: Results of myocardial perfusion scanning were abnormal in 64 patients (68.8%) and normal in 29 patients (31.2%). Of patients with abnormal scans, only 6 (9.4%) had severe CAD at coronary angiography. None of the 29 patients with normal perfusion scans and the 24 patients with fixed defects had severe CAD; however, 6 of 40 patients (15.0%) with reversible perfusion defects had severe CAD at coronary angiography (P = .005). Alcoholic liver disease, reversible perfusion defects at myocardial perfusion scanning, left ventricular systolic dysfunction, and higher low-density lipoprotein (LDL) cholesterol and triglyceride levels were significantly associated with CAD. Defining reversible perfusion defects as a sign of ischemia, and fixed defects and normal perfusion as nonischemic, myocardial perfusion scanning had 100% sensitivity but 61% specificity for severe CAD. The test's accuracy was low (38%).

CONCLUSIONS: The results of reversible perfusion defects on myocardial perfusion scanning were sensitive but not specific for CAD in liver transplantation candidates. The high number of false-positive results decreased the test's accuracy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты