Psychosomatic medicine · 1997
Psychophysiological assessment of respiratory function in panic disorder: evidence for a hyperventilation subtype.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hegel M T, Ferguson R J
Аннотация
OBJECTIVE: Previous research has found differences in respiratory function between panic disorder and other anxiety disorder populations. These differences have been explained as reflecting either a) a specific feature of panic disorder, b) merely a sign of increased general arousal, or c) a result of population sampling error. The current study addressed the question of such differences by using improved methodology over previous research. A preliminary evaluation of respiratory symptoms during panic attacks was undertaken as a means of identifying a respiratory-sensitive subtype of the panic patient.
METHOD: Seventeen panic disorder patients (PD), 18 patients with generalized anxiety disorder (GAD), and 20 normal control (NC) subjects were administered a psychophysiological evaluation composed of baseline, stressor, and recovery phases. Panic patients were measured for the severity of respiratory symptoms during panic attacks. End-tidal CO2 (EtCO2) and respiration rate were measured throughout the psychophysiological evaluation.
RESULTS: PDs demonstrated significantly lower baseline EtCO2 levels than the GADs and NCs, in spite of being equivalent to GADs on baseline anxiety levels. Moreover, panic patients reporting a high level of respiratory symptoms during panic attacks seemed to account for the bulk of observed differences.
CONCLUSIONS: These findings lend support to a group of studies showing differences in respiratory function between panic disorder and other anxiety disorder populations. In addition, this study provides preliminary support for the presence of a distinct "hyperventilation subtype" of panic disorder. The implications of these findings for future research and treatment are discussed.
METHOD: Seventeen panic disorder patients (PD), 18 patients with generalized anxiety disorder (GAD), and 20 normal control (NC) subjects were administered a psychophysiological evaluation composed of baseline, stressor, and recovery phases. Panic patients were measured for the severity of respiratory symptoms during panic attacks. End-tidal CO2 (EtCO2) and respiration rate were measured throughout the psychophysiological evaluation.
RESULTS: PDs demonstrated significantly lower baseline EtCO2 levels than the GADs and NCs, in spite of being equivalent to GADs on baseline anxiety levels. Moreover, panic patients reporting a high level of respiratory symptoms during panic attacks seemed to account for the bulk of observed differences.
CONCLUSIONS: These findings lend support to a group of studies showing differences in respiratory function between panic disorder and other anxiety disorder populations. In addition, this study provides preliminary support for the presence of a distinct "hyperventilation subtype" of panic disorder. The implications of these findings for future research and treatment are discussed.