MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/rcm.8106

Медицинская библиотека · Rapid communications in mass spectrometry : RCM · 2018

Laser ablation synthesis of arsenic-phosphide Asm Pn clusters from As-P mixtures. Laser desorption ionisation with quadrupole ion trap time-of-flight mass spectrometry: The mass spectrometer as a synthesizer.

Kubáček Pavel, Prokeš Lubomír, Pamreddy Annapurna, Peña-Méndez Eladia María, Conde José Elias, Alberti Milan, Havel Josef

СтатьяПеревод в очереди

Аннотация

RATIONALE: Only a few arsenic phosphides are known. A high potential for the generation of new compounds is offered by Laser Ablation Synthesis (LAS) and when Laser Desorption Ionization (LDI) is coupled with simultaneous Time-Of-Flight Mass Spectrometry (TOFMS), immediate identification of the clusters can be achieved.

METHODS

LAS was used for the generation of arsenic phosphides via laser ablation of phosphorus-arsenic mixtures while quadrupole ion trap time-of-flight mass spectrometry (QIT-TOFMS) was used to acquire the mass spectra.

RESULTS

Many new Asm Pn± clusters (479 binary and 369 mono-elemental) not yet described in the literature were generated in the gas phase and their stoichiometry determined. The likely structures for some of the observed clusters arbitrary selected (20) were computed by density functional theory (DFT) optimization.

CONCLUSIONS

LAS is an advantageous approach for the generation of new Asm Pn clusters, while mass spectrometry was found to be an efficient technique for the determination of cluster stoichiometry. The results achieved might inspire the synthesis of new materials.

Для цитирования: Kubáček Pavel, Prokeš Lubomír, Pamreddy Annapurna, Peña-Méndez Eladia María, Conde José Elias, Alberti Milan, Havel Josef. Laser ablation synthesis of arsenic-phosphide Asm Pn clusters from As-P mixtures. Laser desorption ionisation with quadrupole ion trap time-of-flight mass spectrometry: The mass spectrometer as a synthesizer.. Rapid communications in mass spectrometry : RCM. 2018. DOI: 10.1002/rcm.8106.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.