MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1464-410x.2009.09194.x

Медицинская библиотека · BJU international · 2010

Peyronie's disease compromises the durability and component-malfunction rates in patients implanted with an inflatable penile prosthesis.

DiBlasio Christopher J, Kurta Jordan M, Botta Sisir, Malcolm John B, Wan Jim Y, Derweesh Ithaar H, Aleman Michael A, Wake Robert W

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare the durability and complication rates of surgery to implant an inflatable penile prosthesis (IPP) between patients with and without Peyronie's disease (PD).

PATIENTS AND

METHODS

We retrospectively reviewed all patients undergoing IPP surgery at one centre (Memphis) between July 1997 and May 2007. Variables included age at surgery, race, body mass index, presence of PD, brand/type of IPP (two vs three pieces), presence of diabetes mellitus (DM), active tobacco use, and complications. The result were assessed using t-tests, chi-square and regression analysis, with P < 0.05 considered to indicate significant differences.

RESULTS

In all, 79 men were analysed (mean age 59.8 years, range 38.1-81.5). Nine (11%) patients had PD and had a IPP implanted, with penile modelling. Overall, 43 (54%) patients had pre-existing DM and 51 (65%) actively used tobacco. At a mean (range) follow-up of 19.6 (0.1-115.3) months, six (8%) patients had component malfunctions. Of these, three had DM and four actively smoked. Of the nine patients with PD, three developed component malfunctions, vs three (4%) who did not have PD (P= 0.002). Both groups had similar infection rates (P= 0.98). The mean (range) time to component malfunction was 4.3 (0.1-9.6) months, which was longer (but not significantly) in the PD group, with a mean (median, range) of 10.9 (6.3, 1.1-9.6) months, than the 3.0 (1.0, 0.2-7.9) months in the group without PD (P= 0.4). Groups were matched for rates of DM (P= 0.1) and tobacco use (P= 0.2). PD was a significant predictor of component malfunction on both univariate (P= 0.001) and multivariate analysis (P= 0.002) when adjusting for age (P= 0.2), body mass index (P= 0.7), DM (P= 0.3) and tobacco use (P= 0.8).

CONCLUSION

Patients with PD implanted with a IPP, with penile modelling, had significantly higher component malfunction rates. Further, PD independently predicted component malfunction. These findings might be related to stress on the device at the time of surgery, during use, or both. Further study into this relationship is required.

Для цитирования: DiBlasio Christopher J, Kurta Jordan M, Botta Sisir, Malcolm John B, Wan Jim Y, Derweesh Ithaar H, Aleman Michael A, Wake Robert W. Peyronie's disease compromises the durability and component-malfunction rates in patients implanted with an inflatable penile prosthesis.. BJU international. 2010. DOI: 10.1111/j.1464-410x.2009.09194.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.