Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2020

Left ventricular myocardial deformation pattern, mechanical dispersion, and their relation with electrocardiogram markers in the large population-based STANISLAS cohort: insights into electromechanical coupling.

Verdugo-Marchese Mario, Coiro Stefano, Selton-Suty Christine, Kobayashi Masatake, Bozec Erwan, Lamiral Zohra, Venner Clément, Zannad Faiez, Rossignol Patrick, Girerd Nicolas, Huttin Olivier

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: Mechanical alterations in patients with electrical conduction abnormalities are reported to have prognostic value in patients with left ventricular asynchrony or long QT syndrome beyond electrocardiogram (ECG) variables. Whether conduction and repolarization patterns derived from ECG are associated with speckle tracking echocardiography parameters in subjects without overt cardiac disease is yet to be investigated. To report ranges of longitudinal deformation according to conduction and repolarization values in a population-based cohort.

METHODS AND

RESULTS

One thousand, one hundred, and forty subjects (48.6 ± 14.0 years, 47.7% men) enrolled in the fourth visit of the STANISLAS cohort (Lorraine, France) were studied. Echocardiography strain was performed in all subjects. RR, PR, QRS, and QT intervals were retrieved from digitalized 12-lead ECG. Echocardiographic data were stratified according to quartiles of QRS and QTc duration values. Full-wall global longitudinal strain (GLS) was -21.1 ± 2.5% with a mechanical dispersion (MD) value of 34 ± 12 ms. Absolute GLS value was lower in the longest QRS quartile and shortest QTc quartile (both P < 0.001). Time-to-peak of strain was not significantly different according to QRS duration although significantly higher in patients with higher QTc (P < 0.001). MD was significantly greater in patients with longer QTc (32 ± 12 ms for QTc < 396 ms vs. 36 ± 12 ms for QTc > 421 ms; P = 0.002).

CONCLUSION

Longer QTc is related to increased MD and better longitudinal strain values. In a population-based setting, QRS is not associated with MD, suggesting that echocardiography-based dyssynchrony does not largely overlap with ECG-based dyssynchrony.

Для цитирования: Verdugo-Marchese Mario, Coiro Stefano, Selton-Suty Christine, Kobayashi Masatake, Bozec Erwan, Lamiral Zohra, Venner Clément, Zannad Faiez, Rossignol Patrick, Girerd Nicolas, Huttin Olivier. Left ventricular myocardial deformation pattern, mechanical dispersion, and their relation with electrocardiogram markers in the large population-based STANISLAS cohort: insights into electromechanical coupling.. European heart journal. Cardiovascular Imaging. 2020. DOI: 10.1093/ehjci/jeaa148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.